Page 23
ภาษาอั ง กฤษ ENGLISH OM_KC-A60TA_A50TA(TH-EN).indb 21 OM_KC-A60TA_A50TA(TH-EN).indb 21 4/29/11 9:23:00 AM 4/29/11 9:23:00 AM...
Page 24
If the source of the odour still exists, the air purifier may not completely remove the odour. HEPA Filter Deodorizing Filter Pre-Filter (Common illustration has used “KC-A60TA”.) OM_KC-A60TA_A50TA(TH-EN).indb 22 OM_KC-A60TA_A50TA(TH-EN).indb 22 4/29/11 9:23:00 AM 4/29/11 9:23:00 AM...
TROUBLESHOOTING E-16 ......SPECIFICATIONS E-19 ........Thank you for purchasing this SHARP Air Purifier. Please read this manual carefully before using the air purifier. After reading, keep the manual in a conven- ient location for future reference. OM_KC-A60TA_A50TA(TH-EN).indb Sec1:1 OM_KC-A60TA_A50TA(TH-EN).indb Sec1:1...
• If the power cord is damaged, it must be replaced by the manufacturer, its service agent, a Sharp authorized Service Centre or similarly qualified person in order to avoid a hazard. • Only a Sharp Authorized Service Centre should service this air purifier. Contact the nearest Service Centre for any problems, adjustments, or repairs.
CAUTIONS CONCERNING OPERATION • Do not block the intake and/or air outlet. • Do not use the unit near or on hot objects, such as stoves or heaters, or where it may come into contact with steam. • Always operate the unit in an upright position. •...
Indicates the odour intensity of the in the room. room in 3 stages colours. Humidity setting cannot be adjusted. green Faint Strong * KC-A60TA, KC-A50TA ONLY Dust Moniter Indicates the air purity of the room in 5 stages colours. Humidify Light green Clean...
PREPARATION Be sure to remove the power plug from the wall outlet. FILTER INSTALLATION Remove the Back Panel. Deodorizing filter (Black) HEPA filter (White) Remove the Filters from the plas- tic bag. Install the Filters in the correct order as shown. Deodorizing filter (Black) HEPA filter (White) Click...
REFILLING THE WATER TANK When using the Clean Air & Humidify Mode, or the Clean ION Shower Mode. Remove the Water Tank. Fill the Water Tank with tap water. CAUTION • Check to see that there is no water leaking. •...
OPERATION CLEAN AIR & HUMIDIFY Using to quickly clean the air, reduce odours and to humidify. START • Select the desired fan speed.(Ref. E-9) • Unless the power cord has been un- plugged, the operations starts in the pre- vious mode it was operated in. NOTE •...
CLEAN ION SHOWER Releases high-density Plasmacluster ions and discharges strong air flow for 60 minutes. START NOTE • If the “Plasmacluster Ion is OFF, the plasmacluster ion will be not released. • When the operation finishes, the unit will return to the prior operation mode.
USEFUL FUNCTION LIGHT CONTROL Use this function to select the desired brightness. brighter darker turn off CHILD LOCK Operation of the unit display will be locked.It is the same method as starting operation. CANCELLATION more 3 sec. more 3 sec. SOUND INDICATOR SETTING The unit can be set to signal with an audible deep when the Water Tank is empty.
CARE AND MAINTENANCE Be sure to remove the power plug from the wall outlet. FILTER INDICATOR The Indicator Light will turn on after approximately 720 hours. (30days×24hours=720) Reminder to perform maintenance of parts below. After performing maintenance, reset the Filter Indicator. (Ref. E-12) more 3 sec.
CARE AND MAINTENANCE WATER TANK Rinse the inside with a small amount of water. CAUTION •Do not shake the Water Tank with holding the carrying handle. for Stubborn dirt... NOTE Clean inside of the water tank with a soft sponge and the tank cap with a cotton swab or a toothbrush.
Be sure to remove the power plug from the wall outlet. HUMIDIFYING TRAY AND COVER 1. Remove the Humidifying Tray Cover. 2. Rinse the inside of the Humidifying Tray and the Humidifying Tray Cover with a toothbrush. Humidifying Tray Cover CAUTION •...
Page 38
CARE AND MAINTENANCE CARE AND MAINTENANCE DEODORIZIING FILTER HAND WASH ONLY! DO NOT DRY IN CLOTHES DRYER! Remove the dust on the DEODORIZING FILTER. Rinse the DEODORIZING FILTER with water. CAUTION • When washing the filter for the first time, the rinse water may be brown.
FILTER REPLACEMENT Replacement timing Filter life will vary depending on the room environment, usage, and location of the unit. If dust or odour persists, replace the filter. (Refer to “Please read before operating your new Air Purifier”) The following filter life and replacement period is based on the condition of smoking 5 cigarettes per day and the dust collection/deodorization power is reduced by half compared with that of new filter.
TROUBLESHOOTING Before calling for service, please review the Troubleshooting chart below, since the problem may not be a unit malfunction. SYMPTOM REMEDY (not a malfunction) Odours and smoke are not re- • Clean or replace the filters if they appear to be heavily soiled. (Ref.
Page 41
SYMPTOM REMEDY (not a malfunction) When the Roller / Float was removed. • Install the Roller / Float in order below. FLOAT ROLLER Fix the roller in the tray from side way. Float 1. Insert the float under this tab. 2.
Page 42
TROUBLESHOOTING ERROR DISPLAY If error occurs again, contact the Sharp Service Centre. DIGITAL LAMP INDICATION ERROR DETAILS REMEDY INDICA- TION Flashing of the Clean Air & Abnormal humidity filter. Verify if the Humidifying Humidify Indicator Light. Filter, Humidifying Tray and...