Message Description
Type
PROTECTION
WARNING
PROTECTION
WARNING
PROTECTION
WARNING
PROTECTION
WARNING
PROTECTION
46
Code
Description
E504
UNDER VOLTAGE
PROTECTION-CELL
E505
OVER TEMPERATURE.
PROTECTION-CELL
E506
OVER TEMPERATURE.
PROTECTION-CELL
E507
UNDER TEMPERATURE.
PROTECTION-CELL
E508
UNDER TEMPERATURE.
PROTECTION-CELL
E509
CELL VOLTAGE
IMBALANCE
PROTECTION
E510
CELL VOLTAGE
IMBALANCE
PROTECTION
E511
AFE INITIALIZATION
E512
AFE INITIALIZATION
Measures
When the minimum cell voltage is
below Protection level, thus
terminating the system.
Automatically returns to normal
when the minimum cell voltage
goes above the limit value.
When the maximum cell
temperature is above Warning level.
Automatically returns to normal
when the maximum cell
temperature goes below the limit
value.
When the maximum cell
temperature is above Protection
level, thus terminating the system.
Automatically returns to normal
when the maximum cell
temperature goes below the limit
value.
When the minimum cell
temperature is below Warning level.
Automatically returns to normal
when the minimum cell
temperature goes above the limit
value.
When the minimum cell
temperature is below Protection
level, thus terminating the system.
Automatically returns to normal
when the minimum cell
temperature goes above the limit
value.
When the imbalance of the Cell
voltage is above the limit value.
Returns to normal when the
imbalance of the Cell voltage is
below the limit value.
When the imbalance of the Cell
voltage is above the limit value.
Returns to normal when the
imbalance of the Cell voltage is
below the limit value.
AFE initialization failure
Restored to normal mode on AFE
initialization success
AFE communication failure