Bms General Events - Samsung RES 3.6 kWh All In One User Manual

Sdi energy storage system
Table of Contents

Advertisement

Type
PROTECTION
PROTECTION
PROTECTION

7.2.6 BMS General Events

Type
WARNING
PROTECTION
WARNING
Australia (Eng.) 05/2015. Rev1.1
Code
Description
E402
OVER CURRENT TZ
FAULT
E403
TEMPERATURE SENSOR
E404
PV MIS-WIRING
[Table 7-6: System general events protection list]
Code
Description
E501
OVER VOLTAGE
PROTECTION-CELL
E502
OVER VOLTAGE
PROTECTION-CELL
E503
UNDER VOLTAGE
PROTECTION-CELL
Message Description
Measures
If it is not removed until the time
limit is reached, it is converted to a
significant event.
Occurs on INVERTER hardware
protection.
Wait until the event message
disappears. After the event message
is removed, it automatically returns
to normal.
If it is not removed until the time
limit is reached, it is converted to a
significant event.
When the temperature sensor
connection is abnormal.
Wait until the event message
disappears. After the event message
is removed, it automatically returns
to normal.
When the PV mis-wiring states is
abnormal.
Wait until the event message
disappears. After the event message
is removed, it automatically returns
to normal.
Measures
When the maximum cell voltage is
above Warning level.
Automatically returns to normal
when the maximum cell voltage
goes below the limit value.
When the maximum cell voltage is
above Protection level, thus
terminating the system.
Automatically returns to normal
when the maximum cell voltage
goes below the limit value.
When the minimum cell voltage is
below Warning level.
Automatically returns to normal
when the minimum cell voltage
goes above the limit value.