c
Cascade connections for the VC-C4 and VC-C4R
The cascade function of the VC-C4/VC-C4R can be used with the VB150. This
Notes
enables control of up to 4 cameras from a single VB150.
VB
15
0
Connection to separate terminals
● When VC-C4/VC-C4Rs are cascade connected, ID numbers in ascending
order from 1 are assigned to each camera starting with the first camera
connected to camera control connectors CC1 and CC2. Cameras can be
connected to video inputs in any desired combination.
CC1-1
CC1
V B
15
0
CC1-1
CC1
V B
15
0
● In cascade connections, if an abnormality occurs with the first camera in
the connection, control for all other cameras in the cascade may not work
normally.
1
VB
15
0
CC1-2
CC1-3
V1
V2
Example of 4 cameras cascade
V3
V4
connected to 1 camera control connector
CC1-2
CC2-1
CC2
V1
V2
V3
Example of 2 cameras cascade
V4
connected to 2 camera control connectors
2
Cascade connection
CC1-4
CC2-2