User Management Screen [User Mng.] - Panasonic AW-HE130KP Operating Instructions Manual

Hd integrated camera
Table of Contents

Advertisement

Web screen configurations (continued)

User management screen [User mng.]

The users and personal computers (IP addresses) that can access the
unit from personal computers and mobile terminals are registered in the
User mng. screen.
The User mng. screen consists of three tabs, [User auth.], [Host auth.]
and [Priority stream].
User authentication screen [User auth.]
Click the [User auth.] tab of User mng. screen [User mng.].
Configure the user authorization settings for the personal computers and
mobile terminals that can access the unit.
Up to 24 users can be registered.
<NOTE>
• If user authentication fails more than 8 times within a 30-second period
from the same IP address (personal computer), access to the unit will
be disabled for a certain period.
User auth.
User authorization is set to "On" or "Off" here.
Setting value:
On
Perform user authentication.
Off
Do not perform user authentication.
Factory settings:Off
Authentication
Specify the method of user authentication to use.
Setting value:
Digest or Basic
Use digest authentication or basic authentication.
Digest
Use digest authentication.
Basic
Use basic authentication.
Factory settings: Digest or Basic
<NOTE>
• If you change the [Authentication] setting, close the web browser
and perform access again.
• When [User auth.] is set to [On], network connection with the AW-
RP50 will be disabled.
• When [User auth.] is set to [On] while [Authentication] is set to
[Digest], network connection with the AW-RP50, AW-RP120, and
AK-HRP200 will be disabled.
User name
Input the user name.
Maximum number of characters
Invalid characters
Factory settings: blank
1 to 32 half-size characters
" & : ; ¥
Password / Retype password
Input the password.
Maximum number of characters
Invalid characters
Factory settings: blank
<NOTE>
• If you enter a new name for a registered user and click the [Set]
button, the user information will be overwritten.
Access level
Select one of the following settings as the user access level.
Setting value:
This access level allows the user to perform all
1. Administrator
the unit's operations.
This access level allows only live screen [Live]
2. Camera control
operations to be performed. The unit cannot be
set.
This access level enables only Live screen [Live]
3. Live only
to be displayed. The unit cannot be operated
or set.
Factory settings: 3. Live only
User check
You can view registered users by clicking [▼] for [User check].
A registered user is indicated in the form of "Registered user name
[Access level]". (Example: admin[1])
You can delete selected users by clicking the [Delete] button at the
right.
4 to 32 half-size characters
" &