Electrical Adjustments
Group/
Item Name
Item
10 DIMMER_CTRL_LEVEL11
11 DIMMER_CTRL_LEVEL1
1 DIMMER_CTRL_LEVEL13
13 DIMMER_CTRL_LEVEL14
14 DIMMER_CTRL_LEVEL15
15
DIMMER_AVERAGE_POINT
16 DIMMER_AVERAGE_DATA
17 DIMMER_LEVEL_AUTO
18 DIMMER_LEVEL_NORMAL Normal Dimmer Level
19 DIMMER_LEVEL_ECO
0 Lamp check enable
1 VOLTAGE_LEVEL
 DIMMER_LEVEL_HIGH
Group
FAN control
250
0 FAN1 MIN ADJUST (DAC)
1 FAN1 MAX ADJUST (DAC)
 FAN MIN ADJUST (DAC)
3 FAN MAX ADJUST (DAC)
4 FAN3 MIN ADJUST (DAC)
5 FAN3 MAX ADJUST (DAC)
6 Not used
7 Not used
Group
251
Not used
Group
Fan option
252
0 HI-LAND SWITCH
1 SAFETY SWITCH
 FAN MANUAL SWITCH
3 FAN1 MANUAL VOLTAGE
4 FAN MANUAL VOLTAGE
5 FAN3 MANUAL VOLTAGE
6 Not used
Group
Fan tem error Setting (Memorized)
253
0 Temp A Warning (High)
1 Temp B Warning (High)
 Temp C Warning (High)
3 Temp B-A Warning (High)
4 Temp C-A Warning (High)
5 Temp A Warning (Normal)
6 Temp B Warning (Normal)
7 Temp C Warning (Normal)
8 Temp B-A Warning (Normal) Temp. B-A to judge the Temp Error at
9 Temp C-A Warning (Normal) Temp. C-A to judge the Temp Error at
10 Temp A Warning (Eco)
11 Temp B Warning (Eco)
Function
Luminance Level 11 Data for
Dimmer: Dim Level 11 at the less
than the Value
Luminance Level 1 Data for
Dimmer: Dim Level 1 at the less
than the Value
Luminance Level 13 Data for
Dimmer: Dim Level 13 at the less
than the Value
Luminance Level 14 Data for
Dimmer: Dim Level 14 at the less
than the Value
Luminance Level 15 Data for
Dimmer: Dim Level 15 at the less
than the Value
Luminance Data Avarage Point for
Mimmer
Luminance Data Avarage Value for
Dimmer
Current Dimmer Leverl
Eco Dimmer Level
Lamp Voltage
Dimmer level High
DAC Output for Fan
Adjust the tolerance of DAC and Fan
Volage.
* Lamp mode is forced Eco
0: Normal, 1: Hi-Land, -4: Hi-Land
1-3
For test purpose
0: Auto, 1: Manual
Fan Voltage (unit : 0.1V)
Effective only when Fan Maual
switch is 1
Temp. A to judge the Temp Error at
High (Room)
Temp. B to judge the Temp Error at
High (Panel)
Temp. C to judge the Temp Error at
High (Lamp)
Temp. B-A to judge the Temp Error at
High (Clogging Det.)
Temp. C-A to judge the Temp Error at
High (Clogging Det.)
Temp. A to judge the Temp Error at
Normal (Room)
Temp. B to judge the Temp Error at
Normal (Panel)
Temp. C to judge the Temp Error at
Normal (Lamp)
Normal (Clogging Det.)
Normal (Clogging Det.)
Temp. A to judge the Temp Error at
Eco (Room)
Temp. B to judge the Temp Error at
Eco (Panel)
Initial
10
5
10
5
10
5
0
0
0
100
100
100
Normal Ceiling HiLand-
HiLand-
Normal
Ceiling
54
54
5
5
64
64
6
6
70
70
7
7
100
100
100
100
100
100
100
100
54
54
5
5
64
64
6
6
70
70
7
7
100
100
100
100
100
100
100
100
54
54
5
5
64
64
6
6
-41-
range Note
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 16
-
* Read only
-
* Read only
0 - 15
0 - 15
0: Lamp Failure Detection OFF
(White 50% Back), 1 : ON (Blue
100% Back)
Unit: 8bit(Raw Data) * Read only
0 - 15
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 5
0 - 6
0 - 3
0 - 55
0 - 55
0 - 55
30-100
30-100
30-100
0-100
0-100
30-100
30-100
30-100
0-100
0-100
30-100
30-100