Juan Montalvo Pérez
February 9, 2025
Greetings, I **** repairing a Sportman gen 2000 120 volt electric generator and it turns on but the energy that comes out of the receptacle is 8 volts and not 120 as it should be. I checked the mass of the stator and rotor with the voltmeter and it is good. I put a bridge rectifier and a new capacitor of the same model and it still does not generate the voltage of 120 volts. If you can help and guide me I would appreciate it. I will send you a video of the generator. Thank you.
1 comments:
Mr. Anderson
February 11, 2025
Possible causes of low output voltage (8V) from the Sportsman GEN2000LP generator instead of 120V could include:
1. Generator Overload – If the total connected load exceeds the generator's rated capacity (1350 running watts), it may not supply the correct voltage. Reducing the load could resolve the issue. 2. Short in Connected Devices – A faulty or short-circuited electrical device could cause abnormal voltage output. Disconnect all devices and test the generator without any load. 3. Loose Wiring Harness Connection – Loose wiring behind the control panel or at the generator output can affect voltage. Turn off the generator and check for loose connections, tightening them if necessary. 4. Dirty Air Filter – A clogged air filter may reduce engine performance, affecting power generation. Cleaning or replacing the air filter may help. 5. Low Engine Speed – If the engine is not running at the correct speed, the generator may not produce the expected voltage. Checking for issues such as low fuel, dirty spark plug, or incorrect choke position could help.
If the problem persists after checking these factors, further inspection by a qualified technician may be required.
Page 1
GEN2000LP 2000 Surge Watts / 1350 Running Watts LPG PORTABLE GENERATOR INSTRUCTION MANUAL READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance. Every effort has been made to ensure the accuracy of this manual. These instructions are not meant to cover every possible condition and situation that may occur.
Page 2
Parts replaced during warranty repairs will be considered as part of the original product and will have the same warranty period as the original product. This warranty gives you specific legal rights, and you may have other rights that vary from state to state. GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Manual...
CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage. SEEK THE ADVISE OF A LICENSED ELECTRICIAN FOR 120V WIRING GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Manual...
• Do not touch bare wires or outlets (receptacles). • Do not allow children or non-qualified persons to operate this generator. GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Manual...
Page 6
Avoid the use of extension cords if possible. If you choose to use them, be sure they are sized adequately to handle the flow of electricity. An undersized cord can overheat, short out and cause a fire. GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Manual...
Page 8
In addition to the previously described safety information, familiarize yourself with all safety and hazard placards on this generator. GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Manual...
PACKAGE CONTENTS The following items are supplied with this Model GEN2000LP 2000 Surge Watts / 1350 Running Watts Portable LP Generator. Verify that all items are included. STOP! If there are missing items, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time for customer service. DO NOT RETURN THIS GENERATOR TO THE RETAILER.
GENERATOR COMPONENTS Observe the locations and functions of the various components and controls of this generator. GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Manual...
Page 11
To prevent electrical shock from faulty appliances, the generator should be grounded. Connect a length of heavy wire between the ground terminal and the ground source. Consult with a qualified electrician to ensure compliance with local electrical codes. GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Manual...
The correct quantity of oil is equal to the oil capacity of the engine crankcase and is 14 fluid oz for this model GEN2000LP 2000 Surge Watts / 1350 Running Watts Portable LP Generator. Add the correct quantity of oil before operating this generator for the first time.
Disconnect all electrical loads from the generator set before starting the engine. The generator may be hard to start if a load is connected. Step 7 DC OUTPUT no load connected. GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Manual...
5. Confirm that the oil filler/dipstick cap is properly screwed in place when finished verifying the oil level. NOTE: The oil capacity for this Model GEN2000LP 2000 Surge Watts / 1350 Running Watts Portable LP Generator is 14 oz (US).
The choke is used to provide an enriched fuel mixture when starting a cold engine. It can be opened and closed by operating the choke rod manually. Pull the rod out toward CLOSED to enrich the mixture for cold starting GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Manual...
Electrical devices running on AC current may be connected according to their wattage requirements. The rated (running) and surge wattage for this Model GEN2000LP 2000 Surge Watts / 1350 Running Watts Portable LP Generator is 1,350 and 2,000, respectively. Model GEN2000 Rated (Running) Wattage...
Page 17
Even though this Model GEN2000LP Portable LP Generator has an overall rated wattage of 2000, do not attempt to draw more than 1350 Watts (20 A) from any ONE of the 120 Volt outlets. Draws higher than 1350 Watts (20 A) will damage this generator and void the warranty.
3. Turn the engine switch “off”. 4. Turn the fuel valve to the “off” position. Allow this generator to cool down before touching areas that become hot during operation. GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Manual...
(see “Changing/Adding Oil” in this section of this manual). 5. Confirm that the oil filler/dipstick cap is properly in place when finished verifying the oil level. GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Manual...
The oil level in this generator should be checked before each use. (See Figure 10.) When the oil level is low, add oil until the level is sufficient to operate this generator. The oil capacity for this Model GEN2000LP 2000 Surge Watts / 1350 Running Watts Portable LP Generator engine is 14 fluid oz. To drain the oil from this generator: The oil should be changed after the first 20 hours of operation.
This LP Generator is more efficient than traditional gasoline generators. As such, the spark plug on this LP generator will last longer. Please contact Customer Service if you have questions regarding the spark plug. (Figure 16) GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Manual...
• Do not obstruct any ventilation openings. • Do not drop or strike this generator while moving it. • Store this generator in a cool dry area, free of excessive dust. GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Manual...
Be certain the plug in connectors are pushed together all the way. Bad connecting wires/cables. Try a different extension cord. Bad electrical device connected to generator. Disconnect device, try connecting another device. GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Manual...
Need help?
Do you have a question about the GEN2000LP and is the answer not in the manual?
Questions and answers
Greetings, I **** repairing a Sportman gen 2000 120 volt electric generator and it turns on but the energy that comes out of the receptacle is 8 volts and not 120 as it should be. I checked the mass of the stator and rotor with the voltmeter and it is good. I put a bridge rectifier and a new capacitor of the same model and it still does not generate the voltage of 120 volts. If you can help and guide me I would appreciate it. I will send you a video of the generator. Thank you.
Possible causes of low output voltage (8V) from the Sportsman GEN2000LP generator instead of 120V could include:
1. Generator Overload – If the total connected load exceeds the generator's rated capacity (1350 running watts), it may not supply the correct voltage. Reducing the load could resolve the issue.
2. Short in Connected Devices – A faulty or short-circuited electrical device could cause abnormal voltage output. Disconnect all devices and test the generator without any load.
3. Loose Wiring Harness Connection – Loose wiring behind the control panel or at the generator output can affect voltage. Turn off the generator and check for loose connections, tightening them if necessary.
4. Dirty Air Filter – A clogged air filter may reduce engine performance, affecting power generation. Cleaning or replacing the air filter may help.
5. Low Engine Speed – If the engine is not running at the correct speed, the generator may not produce the expected voltage. Checking for issues such as low fuel, dirty spark plug, or incorrect choke position could help.
If the problem persists after checking these factors, further inspection by a qualified technician may be required.
This answer is automatically generated