7. Remove drive spacer(s) (not used on 4.5 cu. in. dis-
placement units).
8. Remove drive.
9. Remove spacer plate.
10. Remove seal from housing.
Control End Disassembly
11. Remove housing from vise. Place housing on a
clean soft cloth to protect surface finish. Use a thin−
blade screwdriver to pry retaining ring from housing, as
shown in Fig. 30.
12. Rotate spool and sleeve until pin is horizontal. Push
spool and sleeve assembly forward with your thumbs
just far enough to free gland bushing from housing, see
Fig. 31. Remove bushing.
Hydraulic System
Page 4 − 42
Figure 29
Figure 30
Figure 31
Reelmaster 4000−D