Culligan dealer employs trained service and maintenance personnel who are experienced in the installation, function and repair of Culligan equipment. This publication is written specifically for these individuals and is intended for their use. We encourage Culligan users to learn about Culligan products, but we believe that product knowledge is best obtained by consulting with your Culligan dealer.
Service Manual CULLIGAN SILVER SERIES ™ AND GOLD SERIES ™ AUTOMATIC WATER CONDITIONER MODELS FROM 2000 Table of Contents Page Introduction ............... 2 Specifications ............3 Familiarization ............5 Programming ............14 Manual Cycling ............16 Service Check ............17 Parts Replacement Guide ........
This publication is based on information available when approved for printing. Continuing design refinement could cause changes that may not be included in this publication. * Verified using hardness surrogate per ANSI/NSF Standard 44. CULLIGAN SILVER SERIES AND GOLD SERIES WATER SOFTENERS...
Specifications Culligan Silver Series Water Conditioners with Time Clock, Aqua-Sensor Device or Soft-Minder Meter ™ ® ® 9” Model 12” Model Control Valve 5-cycle, Reinforced Thermoplastic 5-cycle, Reinforced Thermoplastic Overall Conditioner Height 51 in 51 in 1 295 mm 1 295 mm...
Page 6
3 Measured from top of underbedding to top surface of tank threads. 4 Backwash at 120 psi (830 kPa). 5 10 minute backwash, 4 lb (1.8 kg) 9” model or 6 lb (2.7 kg) 12” model salt dosage. CULLIGAN SILVER SERIES AND GOLD SERIES WATER SOFTENERS ™...
CIRCUIT BOARD The AccuSoft microprocessor circuit board controls every function of the Culligan Silver Series and Gold Series ™ water softeners. This board has several unique features which allow it to perform a variety of functions. Familiarization of the board is essential for a thorough understanding of the softener.
Page 8
Minder connection is located in the upper left side of the board. Just below the meter connection is a connection marked 'BATT', which is for the optional battery back-up. All terminals are clearly marked to ease installation. FIG. 2 CULLIGAN SILVER SERIES AND GOLD SERIES WATER SOFTENERS ™ ™...
Page 9
NOTICE: Dip switch #3 needs to be in the "ON" position for the meter to correctly count gallons. TIME CLOCK OPERATION When the microprocessor is set-up as a time clock unit, the Culligan Silver Series and Gold Series control will ™...
24-5/8 62.5 22-5/8 57.5 18-1/2 16-1/2 45,400 — — 19-1/2 49.5 17-1/2 44.5 45,500 — — 27-3/8 69.5 25-3/8 64.5 20-1/2 52.1 18-1/2 46,100 — — 28-3/4 26-3/4 21-1/2 54.6 19-1/2 49.5 CULLIGAN SILVER SERIES AND GOLD SERIES WATER SOFTENERS...
Page 11
3. Treated Water Volume Set Point Calculate the treated water volume set point using the following information: • Softening capacity — Grains (based upon salt dosage setting). • Compensated hardness of water supply — Grains Per Gallon • Estimated daily water usage — Gallons Per Day (refer to Table 5) TABLE 5 - Daily Water Usage Persons in Household Gallons Per Day...
Page 12
To have the display constantly lit, press the STATUS button until the number 10 icon is lit. Next, press the UP arrow. A “d” for disable will appear in the display. To have the display blank again , press the UP arrow. An “E” will appear in the display . CULLIGAN SILVER SERIES AND GOLD SERIES WATER SOFTENERS...
Page 13
FAILURE MODE The Culligan Silver Series and Gold Series control is equipped to detect a motor or piston which is locked in a frozen position. The AccuSoft circuit board will apply power to the motor for 30 seconds. If there is no change in the ™...
Page 14
CULLIGAN SILVER SERIES AND GOLD SERIES WATER SOFTENERS ™ ™...
5 and 40 minutes by using the up and down arrows. A number “5” will appear at the bottom of the display while in this mode. Press to increase or to decrease CULLIGAN SILVER SERIES AND GOLD SERIES WATER SOFTENERS ™ ™...
Page 17
Press status again to display the Brine/Rinse Time in minutes. The settings can be adjusted using the up and down arrows (37-85 min for 9”, 35-89 min for 12”). A number “6” will appear at the bottom of the display while in this mode. Press to increase or to decrease...
Press the up arrow. An 'H' will appear in the display. The unit is in the HOME position. The 'REGEN' enunciator is no longer blinking. An 'H 20' will appear on the Aqua-Sensor® models. Press the status key. Time-of-Day appears in the display. CULLIGAN SILVER SERIES AND GOLD SERIES WATER SOFTENERS ™...
Service Check The service check mode allows one to view the instantaneous flow rate, the days since the last regeneration, the total number of regenerations, the regenerations in the past fourteen days, and the gallons remaining. To enter the service check mode, follow these steps: Press the status key to move past steps 1-10 until the display is blank.
CAUTION: The wire connectors must be connected to the circuit board properly. The wires must exit the plug-in connector opposite of the raised white base of the circuit board connector. FIG. 4 CULLIGAN SILVER SERIES AND GOLD SERIES WATER SOFTENERS ™...
Refer to Figure 5 for assembly and disassembly of the various valve components listed below. DRIVE MOTOR ASSEMBLY Remove the drive motor cam switches by removing the one screw holding the switches to the motor Remove the E-ring holding the drive motor cam to the camshaft with a flat tip screwdriver. Lift the cam off the shaft.
Page 22
NOTICE: The eductor piston & sleeve assemblies are unique to the softener, filter, and Super S controls. Refer to the parts list to ensure that the proper assembly is used. CULLIGAN SILVER SERIES AND GOLD SERIES WATER SOFTENERS ™...
EDUCTOR ASSEMBLY Refer to Figure 7 and the following instructions for replacement of the eductor: Remove the three screws and the eductor plate Remove the eductor screen by lifting it from the eductor body. Remove the eductor body by grasping one of the projections with the pliers and gently pulling upward. Reverse the procedure to reassemble.
Household Aqua-Sensor Sensing Device ® Troubleshooting Guide The following procedure will help you diagnose problems in units equipped with Aqua-Sensor sensing device. Because many “sensor problems” are actually regeneration problems, it contains a combination of sensor diagnostics and routine control valve and brine system checks. Refer to the Troubleshooting Flow chart on page 25 for the recommended sequence.
Page 26
Backwash the unit for 2 – 3 minutes after installing the probe to eliminate any air pockets in the unit. Check the unit for regeneration function (salt dosage, brine draw, rinse and refill) CULLIGAN SILVER SERIES AND GOLD SERIES WATER SOFTENERS ™...
AQUA-SENSOR TROUBLESHOOTING FLOWCHART ® Problem: Regenerates Never Nightly Regenerates Diagnostics Sequence: Check water usage: Is there salt in higher than expected? the brine tank? Gen 3: Check step 6. Does the unit draw The default setting is 71 brine properly? minutes.
Iron or Hardness bleed in C. Eductor screen or nozzle plugged C. Clean or replace eductor nozzle softener and/or screen CULLIGAN SILVER SERIES AND GOLD SERIES WATER SOFTENERS ™ ™...
Page 29
PROBLEM CAUSE SOLUTION 5. Hard water to service (cont.) D. Incorrect programming (Salt D. Refer to the 'Programming' section dosage too low for influent and verify that settings are correct hardness) E. Insufficient water flowing to salt E. Verify that refill settings are storage tank correct and clean the refill flow restrictor...
Page 30
B. Increase line pressure to a brine draw time minimum of 20 psi (140 kPa) C. Too much brine in the storage C. Refer to problems 9 & 10 tank CULLIGAN SILVER SERIES AND GOLD SERIES WATER SOFTENERS ™ ™...
This will help to eliminate confusion at a future date. NOTICE: When using the 0.80 gpm flow control, shift the #5 dip switch to the ON position. This enables the fast refill mode for the softener. FIG. 8 CULLIGAN SILVER SERIES AND GOLD SERIES WATER SOFTENERS ™...
Page 33
TABLE 11 - Brine Valve "A" Dimension REFILL TIME (MIN) BRINE TANK “A” DIMENSION POUND STANDARD FAST 160 LB 250 LB 375 LB SALT (0.45 gpm) (0.80 gpm) (13") (16") (18") 2.23 1.30 5-1/4 4-1/2 3.08 1.73 7-3/4 6-5/8 5-1/2 3.83 2.17 9-1/2...