Download Print this page
Kohler 20RESA Installation Instructions

Kohler 20RESA Installation Instructions

Multi-fuel lp vapor/natural gas
Hide thumbs Also See for 20RESA:

Advertisement

r
The Kohler
Advantage
D
High Quality Power
Kohler home generators provide advanced voltage and
frequency regulation along with ultra-low levels of
harmonic distortion for excellent generator power quality to
protect your valuable electronics.
D
Extraordinary Reliability
Kohler is known for extraordinary reliability and
performance and backs that up with an industry-leading
5-year or 2000 hour warranty.
D
Powerful Performance
Exclusive Powerboostt technology provides excellent
starting power. The Kohler 14 kW generator can easily
start and run a 5 ton air conditioner without dropping power
to other appliances.*
D
Exclusive 100% Corrosion-Proof Enclosure
The bold new Kohler design is completely corrosion proof,
even in harsh seaside environments, and is
impact-resistant even at --34_ C (--30_ F).
D
Fast Response
Kohler's unique Fast-Responset excitation system
delivers excellent voltage response and short-circuit
capability.
D
Quiet Operation
Kohler home generators provide quiet, neighborhood-
friendly performance.
Generator Ratings
Model
Voltage
120/240
14RESA
115/230
120/240
20RESA
115/230
RATINGS: Standby ratings apply to installations served by a reliable utility source. All single-phase units are rated at 1.0 power factor. The standby rating is applicable to variable loads with an average
load factor of 80% for the duration of the power outage. No overload capacity is specified at this rating. Ratings are in accordance with ISO--3046/1, BS5514, AS2789, and DIN 6271. GENERAL
GUIDELINES FOR DERATING: ALTITUDE: Derate 4% per 305 m (1000 ft.) elevation above 153 m (500 ft.). TEMPERATURE: Derate 2% per 5.5_C (10_F) temperature increase above 16_C (60_F).
Availability is subject to change without notice. The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever.
Contact your local Kohler Co. generator distributor for availability.
*
Check the appliance manufacturer's specifications for actual power requirements. Consult a Kohlerr Power Systems professional to calculate your exact residential power system
requirements.
Phase
Hz
Alternator
1
60
2F5
1
50
2F5
1
60
2F7
1
50
2F7
G4-209 (14/20RESA) 12/11
Models:

Standard Features

D
RDC2 Controller
d
One digital controller manages both the generator set
and transfer switch functions (with optional Model RXT
transfer switch).
d
Designed for today's most sophisticated electronics.
d
Electronic speed control responds quickly to varying
household demand.
d
Digital voltage regulation protects your sensitive
electronics from harmonic distortion and unstable power
quality.
d
Two-line, backlit LCD display with adjustable contrast is
easy to read, even in direct sunlight or low light.
D
Kohler Command PRO Engine Features
d
Kohler Command PROr OHV engine with hydraulic
valve lifters for reliable performance without routine
valve adjustment or lengthy break-in requirements
d
Powerful, reliable air-cooled performance
d
Simple field conversion between natural gas and LP
vapor fuels while maintaining emission certification
D
Designed for Easy Installation
d
Polymer base eliminates the need for a concrete
mounting pad, reducing installation time and cost
d
Hinged, locking roof
d
Fuel and electrical connections through the enclosure
wall eliminate the need for stub-ups through the bottom
d
Load connection terminal block allows easy field wiring
d
Designed for outdoor installation only
D
Certifications
d
Meets emission regulations for U.S. Environmental
Protection Agency (EPA) phase 2 small off-road engines
and CA 2006 and later LSI engines with both LP vapor
and natural gas
d
UL 2200 listed (60 Hz model)
d
CSA certification available (60 Hz model)
d
Approved for stationary standby applications in locations
served by a reliable utility source
d
Model 14RESA is also approved for non-standby
(off-grid) applications (18 month or 1000 hour warranty
applies for non-standby applications)
Standby Ratings
Natural Gas
kW/kVA
Amps
12/12
50.0
10/10
43.5
18/18
75.0
14/14
60.8
14/20 RESA
Multi-Fuel
LP Vapor/Natural Gas
LP Gas
kW/kVA
Amps
14/14
58.3
11/11
47.8
20/20
83.3
15/15
65.2

Advertisement

loading
Need help?

Need help?

Do you have a question about the 20RESA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kohler 20RESA

  • Page 1: Standard Features

    Exclusive Powerboostt technology provides excellent wall eliminate the need for stub-ups through the bottom starting power. The Kohler 14 kW generator can easily Load connection terminal block allows easy field wiring start and run a 5 ton air conditioner without dropping power Designed for outdoor installation only to other appliances.*...
  • Page 2 30 (100) 1 1/4 Exhaust System 14RESA 20RESA 46 (150) 1 1/4 1 1/4 1 1/4 Exhaust temperature exiting the enclosure at rated kW, dry, _C (_F) 260 (500) 61 (200) 1 1/4 1 1/4 1 1/4 G4-209 (14/20RESA) 12/11...
  • Page 3: Fuel Requirements

    Unloaded full-speed exercise and normal operation. Loaded full-speed exercise (Model RXT ATS required) Model 20RESA sound level is 64 dBA during weekly engine Front-access mini USB connector for SiteTecht connection exercise and 69 dBA during full-speed generator diagnostics Front access mini-breaker protects the alternator and normal operation.
  • Page 4 0_C [32_F ] ) ATS control (Model RXT ATS required) Source voltage and frequency settings - Fuel regulator heater pad (20RESA; recommended for Engine start time delay reliable starting at temperatures below --18_C [0_F ] )

This manual is also suitable for:

14resa