  • Page 1 USER MANUAL GDAŃSK integra_u_e 08/07...
  • Page 2 The latest EC declaration of conformity and product approval certificates are available for downloading on website www.satel.pl The INTEGRA alarm control panels meet requirements as per CLC/TS 50131-3, Grade 3, and have been certified by Det Norske Veritas Certification AS, Norway.
  • Page 3 Changes in the INTEGRA control panels with firmware in version 1.05 Support of new INT-SCR-BL – multifunctional keypad which can work as a partition modules keypad (identified as INT-S/SK), partition keypad with reader (identified as INT-SCR) or entry keypad (identified as INT-ENT) INT-ORS –...
  • Page 4: Table Of Contents

    User Manual INTEGRA CONTENTS ..........................4 ENERAL ......................4 BOUT THIS MANUAL ..............4 ECHNICAL RELIABILITY OF THE ALARM SYSTEM ..................5 LARM SYSTEM OPERATING COSTS INTEGRA ....................5 CONTROL PANEL 5.1 B ................. 5 ASIC FUNCTIONS OF THE CONTROL PANEL 5.2 C...
  • Page 5 INTEGRA SATEL Masters ..............................43 Users ................................43 Zone bypasses ............................46 Set time..............................46 Troubles ..............................47 Events ...............................47 Reset zones..............................48 Clear latched outputs..........................48 Change options............................49 Tests .................................50 Service access............................52 Open door ..............................52 Outputs control ............................52 Service mode............................53 Take SM over ............................53 Downloading .............................53 CLC/TS 50131-3 ............
  • Page 6: General

    This Manual allows you to familiarize yourself with the basic operation of modules designed to control the operation of alarm systems based on the INTEGRA control panels and with the functions performed by these panels. The INTEGRA includes four alarm control panels: INTEGRA 24, INTEGRA 32, INTEGRA 64 and INTEGRA 128.
  • Page 7: Alarm System Operating Costs

    5. INTEGRA CONTROL PANEL The INTEGRA alarm control panel is designed for the security supervision in small, medium- size and large facilities. The supervision is not limited to protection against burglary, but it may also include monitoring of the facility for correct functioning for 24 hours a day. The status of the alarm system is monitored on a continuous basis.
  • Page 8: Control Panel Performance

    32 armed independently partitions, • control of individual system parts from independent keypads (maximum 8 LCD keypads and 64 partition LED keypads for the INTEGRA 64 and the INTEGRA 128), • individual control of the output types of MONO , BI...
  • Page 9: Operation Of Integra Control Panel

    LCD keypads and partition keypads are mainly used for operating the alarm system based on the INTEGRA control panel. Additionally, the control panel supervises and registers usage of code locks as well as proximity card and Dallas chip readers, installed at the doors in individual spaces of the facility.
  • Page 10: Lcd Keypads

    (for approx. 40 seconds) the keypad processor will restart and display the version numbers of keypad and control panel programs. 6.2 LCD K EYPADS SATEL offers the following LCD keypads for INTEGRA control panels: − INT-KLCD-GR/INT-KLCD-BL − INT-KLCDR-GR/INT-KLCDR-BL − INT-KLCDK-GR − INT-KLCDL-GR/INT-KLCDL-BL −...
  • Page 11 INTEGRA SATEL Fig. 1. View of INT-KLCDR-GR keypad. Fig. 2. View of INT-KLCDS-GR keypad.
  • Page 12: Display

    User Manual INTEGRA Fig. 3. View of INT-KLCDK-GR keypad. 6.2.1 Display The LCD keypad comes with a large LCD display (2 x 16 characters) with permanent or temporary backlighting; the temporary backlighting is activated either by pressing any key or by violation of any zone (service setting).
  • Page 13: Led Indicators

    INTEGRA SATEL The letters provided on numerical keys can help to memorize the access code by associating it with a particular word (e.g. the code "[7][8][2][7][8]" corresponds to the word "START"). The [#] and [ok] keys are electrically connected to each other and may be used interchangeably.
  • Page 14: Audible Signals

    User Manual INTEGRA 6.2.4 Audible signals When using the keypad the following signals, characteristic of some situations, can be heard PROG. • One long beep – refusal of arming - the zone, which shouldn't be violated at the time of...
  • Page 15 INTEGRA SATEL user has access to a single partition only, entering the code and pressing [#] results in immediate arming or disarming (if the partition is armed). Entering the code and pressing [ * ] displays the list of functions accessible from the User Menu.
  • Page 16: Selecting Functions From Menu

    User Manual INTEGRA For each of the functions the installer determines the number of partition, zone or output it refers to. The user, who wants to perform the given function must have an appropriate authority level and access to the selected partitions.
  • Page 17: Graphic Mode

    32, they are displayed in groups, 32 items in each group (up to 4 groups with 32 zones/outputs each for INTEGRA 128). The number of the currently displayed group is indicated by two lit LEDs labeled [GROUP] (see description of the LEDs, p.
  • Page 18: Reading Alarm Source Name

    User Manual INTEGRA 6.3.4 Reading alarm source name The installer can enable the function of displaying the name of alarm source on the LCD keypad, without necessity of entering the code. In such a case, the partition or zone name is displayed on the keypad screen when an alarm occurs.
  • Page 19: Partition Keypads

    INTEGRA SATEL 6.4 P ARTITION KEYPADS SATEL offers the following partition keypads for INTEGRA control panels: − INT-S-GR/INT-S-BL − INT-SK-GR These keypads differ by size and shape. The keypads are available with green or blue backlighting of the keys. Designation of the models with green display ends with "GR" letters, and that of the models with blue display –...
  • Page 20 User Manual INTEGRA Fig. 5. INT-SK-GR partition keypad. The partition keypads are provided with LED indicators: – (red) – permanent lighting of the LED means alarm. After the alarm time ALARM expires, blinking of the LED indicates the alarm memory. The LED goes off after the...
  • Page 21 INTEGRA SATEL • Two long beeps – the code is unknown to the control panel. • Two short beeps – acceptance of the first of two codes required for arming or disarming. • Three long beeps – the code cannot control this partition.
  • Page 22 User Manual INTEGRA Notes: • If the given partition is armed, and the keypad is also used to operate the electromagnetic door lock, then entering [CODE][ * ] will disarm the partition and open the door - unless the partition is temporarily blocked.
  • Page 23: Multifunctional Keypad With Proximity Card Reader

    INTEGRA SATEL 6.5 M ULTIFUNCTIONAL KEYPAD WITH PROXIMITY CARD READER INT-SCR-BL multifunctional keypad with proximity card reader can work as: • partition keypad (see section: P ARTITION KEYPADS • partition keypad with proximity card reader – having the functionality of partition keypad, enhanced by an option to identify users, based on the proximity card;...
  • Page 24 User Manual INTEGRA Functions executed after entering the access code and confirming it with the key or presenting the card (the function to be executed depends on the user authority level, keypad settings and security system status): – relay activation –...
  • Page 25: Operation In Entry Keypad Mode (Int-Ent)

    INTEGRA SATEL 4. The change of access code has been blocked, because the code has been „hit" by another user trying to change his own code. If the option to remind of the need to change the code is enabled, each use of such a „hit" code will be signaled by three double beeps.
  • Page 26: Code Locks

    PROG. ELAY ACTIVATION TIME 6.6 C ODE LOCKS SATEL offers the following code locks for the INTEGRA control panels: − INT-SZ-GR/INT-SZ-BL − INT-SZK-GR They differ by their size and shape. The code locks are available with green or blue backlighting. Designation of the models with green backlighting ends with "GR" letters, while that of the models with blue backlighting –...
  • Page 27 INTEGRA SATEL Fig. 7. Code lock type INT-SZ-GR/INT-SZ-BL. Fig. 8. Code lock type INT-SZK-GR. When all the LEDs are alternately blinking (from top to bottom), there is no communication between the code lock and the control panel. This situation may occur when the STARTER program is running in the control panel or the cable connecting the code lock to the control panel is damaged.
  • Page 28: Proximity Card And Dallas Chip Reader

    User Manual INTEGRA The basic function of the code lock is to control access to the room where the door provided with electric catch, bolt or electromagnetic interlock is installed. The lock may also be used for partition control during a guard round in the facility.
  • Page 29: Codes And Users

    3. User code – the remaining codes entered in the system by master users or users (authorized to edit the user). These are codes for everyday operation of the system. The number of available codes depends on the control panel size: – INTEGRA 24: 16 – INTEGRA 32: 64 – INTEGRA 64: 192 –...
  • Page 30: Prefixes

    ROXIMITY CARDS CHIPS Each user of the INTEGRA alarm system (master user, guard, or ordinary user) may have one proximity card and/or DALLAS chip assigned to him at the stage of user creating or editing. The card/chip may be deleted or assigned by installer (service) in case of master...
  • Page 31: Deleting Cards/Dallas Chips

    (as programmed by the installer). The INTEGRA control panel enables individual control of armed status in each partition of the object. A single partition, several partitions and/or all partitions may be armed.
  • Page 32 User Manual INTEGRA • If the option W is enabled, the partitions are armed from the ARN WHILE ARMING IF TROUBLE LCD keypad and there are troubles in the system, the control panel will inform the user of it with a suitable message before arming. Pressing the key [1] will arm the partition(s), and pressing the key [2] will display information on troubles.
  • Page 33: Alarms

    INTEGRA SATEL not violated during this time, the control panel will display a list of faulty zones (number and name of zone) and will not arm the system. Pressing the digit 1 key during the process of countdown will interrupt the test and arm the system in normal mode, while pressing the [ * ] key will make it possible to cancel the arming.
  • Page 34: Alarm Messaging By Telephone

    (the system installer may install voice synthesizers to enable playback of any prerecorded sounds). The INTEGRA 128 control panel makes it possible to reproduce 32 different voice messages. Who will be notified of which alarm by the control panel is specified by the installer, who programs the corresponding telephone numbers and defines the rules of messaging.
  • Page 35: Answering Phone Calls

    6.14 A NSWERING PHONE CALLS The INTEGRA control panel is able to answer phone calls and transmit information on the system status. It makes also possible to call control functions with the use of telephone. Each ordinary user (at the stage of user entering or editing) may have a telephone code assigned (which is not to be mixed with the code acknowledging receipt of a telephone message on alarm).
  • Page 36: Other Functions Using Telephone Line

    User Manual INTEGRA • Now the control panel waits for the (two-digit) switch number to be entered. Entering the telephone number from the telephone keypad will switch the relay status to the opposite one. Three short beeps mean that the relay is switched off and four short and one long beeps - that the relay is switched on.
  • Page 37: User Function Menu

    INTEGRA SATEL 7.1.1 User function menu Note: As the menu changes dynamically, depending on the programmed system parameters and the user authority level, not all functions are visible to the user. [USER CODE][#] (calling the functions arming / disarming) Arm all...
  • Page 38 INTEGRA User Manual Masters* New master Edit master Select Code Rights Assign authority Keypads etc. Assign keypads Read prox. card Select reader Read card for the first time Read card for the second time Erase prox.card Read DALLAS Select reader...
  • Page 39 INTEGRA SATEL Users New user Edit user Select Code Telephone code Object Assign partitions Type Select type Rights Assign authority Keypads etc. Assign keypads Schedule Existence time Bypass time Read prox. card Select reader Read card for the first time Read card for the second time Erase prox.card...
  • Page 40 INTEGRA User Manual Zone bypasses Select zones Set time Set time Set date Troubles Events Selected Select events Select partition View Reset zones Clear latched outputs Change options Keypad chime Outputs chime Outputs chime blocking Select partitions Partition timers Select partition...
  • Page 41 INTEGRA SATEL Station 1A test Station 1B test Station 2A test Station 2B test Messaging test Answering test View masters** Keypad name File in DloadX Panel version IP/MAC ETHM-1 Modules version Time synchron. Service access** Service access time Open door...
  • Page 42: Description Of User Functions

    User Manual INTEGRA 7.2 D ESCRIPTION OF USER FUNCTIONS View cleared alarms The function is available, provided that the user has not viewed the violated zones. It makes it possible to check which zones triggered the alarm. After completion of the viewing, the function will be unavailable.
  • Page 43: Disarm (2Codes)

    INTEGRA SATEL the other code in the same way as for the partitions armed with a single code. The user who has entered the first code has the option to cancel his "consent" to arming of selected partitions (see description of the C function).
  • Page 44: Set Auto-Arming Delay

    User Manual INTEGRA Set auto-arming delay The function puts off (delays) arming of a timer-controlled partition (auto-arming). It is used for programming the value of time interval by which the moment of automatic arming of a partition is to be delayed. The maximum delay time is 4 hours, 33 minutes and 3 seconds.
  • Page 45: Change Prefix

    INTEGRA SATEL In the first two cases, the procedure of entering a new code is simple: having started the function, enter the new code and confirm it by pressing the [#] key. If the code has been guessed, the procedure is more complicated, as it requires confirmation...
  • Page 46 User Manual INTEGRA status of partitions he has access to, and control the R type outputs by EMOTE SWITCH phone (see section "Answering Phone Calls"). Partitions – assignment of partitions the user has access to (i.e. he is authorized to arm or disarm them, clear alarms, and start the control functions).
  • Page 47 INTEGRA SATEL Entering this code on the electric lock keypad or execution of access by means of a proximity card or DALLAS chip will generate the “User Access" type of event. When the guard has the authority of access to partitions, the partitions may be controlled in much the same way as with using the Normal type of code (calling function in LCD keypad: [CODE][ * ]).
  • Page 48: Zone Bypasses

    User Manual INTEGRA - Downloading - Outputs control - GuardX using - Clear latched outputs Notes: • The right C defines whether the user always may disarm the system AN ALWAYS DISARM (option selected) or only when he previously armed it himself (option deselected).
  • Page 49: Troubles

    INTEGRA SATEL New data should be entered from the keypad by typing the correct digit at the place of the cursor flashing. After the digit is entered, the flashing indicator moves to the next position on the right. The cursor can also be moved by using the keys.
  • Page 50: Reset Zones

    User Manual INTEGRA Tpar partition timer, MnPl control panel main board. Some of event descriptions allow readout of two identifiers, for example: partition number and zone number, keypad number and user number, etc. To read the second identifier, press the key.
  • Page 51: Change Options

    INTEGRA SATEL Change options This function controls the “CHIME" type signaling and allows setting the partition user timer which automatically arms and disarms the partition, sets the mode of service code access to the system, and deletes the service message.
  • Page 52: Tests

    (numbers around the keypad display) which corresponds to the zone number in the system. The installer assigns symbols (characters) to particular situations. Information on zones is displayed, depending on the control panel size, in 1, 2 or 4 (INTEGRA 128) sets (see p. 11, description of ] LEDs).
  • Page 53 INTEGRA SATEL Radio devices – the function makes it possible to check the radio signal level in the ABAX wireless system devices working in conjunction with the control panel. Zone Test – the function makes it possible to check the working capacity of zones (detectors and other devices connected to the zones).
  • Page 54: Service Access

    User Manual INTEGRA been programmed. The function makes it possible to manually initiate synchronization of the control panel clock with the time server. Note: If the time synchronization is going on (initiated automatically or manually), the function is unavailable. No additional message is displayed at the time of exiting the function.
  • Page 55: Service Mode

    INTEGRA SATEL Controlling the R type of outputs EMOTE SWITCH The control is effected by means of the [#] or key. Pressing the key will activate the output for a preprogrammed period of time or toggle the status of the output. It depends on the output settings.
  • Page 56: Cclc/Ts 50131-3

    User Manual INTEGRA possible to start direct communication via RS port, as well as indirect communication via the telephone line (with the use of either external or internal modem). To start a telephone call it is necessary to program the service computer telephone number.
  • Page 57: Ppendix A

    1st monitoring station trouble 2nd monitoring station trouble RTC chip trouble CRC error in RAM memory INTEGRA panel restart No connection with MS 1 (ETHM) No connection with MS 2 (ETHM) No connection with MS 1 (GSM) No connection with MS 1 (GSM) Time server trouble [n]=0–7...
  • Page 58 User Manual INTEGRA [n]=0–63 expander number No expander [n]: [n]=0–63 expander number Changed exp.[n]: [n]=0–63 expander number Exp. [n] tamper: [n]=0–63 expander number Reader A exp.[n]: [n]=0–63 expander number Reader B exp.[n]: [n]=0–63 expander number Overload exp.[n]: [n]=0–63 expander number BUS shrt.exp.[n]:...
  • Page 59: Ppendix B

    10. A PPENDIX EXPLANATION OF SOME TECHNICAL TERMS All definitions apply to the alarm system based on the INTEGRA control panel. STARTER The program activated in the control panel after power-up to check integrity of the basic program stored in FLASH memory and to enable a new control panel firmware version to be loaded into this memory.
  • Page 60: Appendixc

    Change your code (press #) This message is displayed when the user has the right to change the code and should make this change (see User Manual, INTEGRA, description of function Change own code). Confirm the message. Arm all Arm selected , all partitions accessible to the user will be armed.
  • Page 61 INTEGRA SATEL • using partition numbers – in the graphic mode described below. This is the mode for the user who exactly knows the numbers of partitions in the alarm system, or the user, who wants to quickly check how many partitions are not armed yet.
  • Page 62: System Disarmed

    User Manual INTEGRA [1][1][1][1][#] Enter the user code (factory set master user code for Object 1). You can also enter the code of any user who has access to Partition 2 and is authorized for disarming. Disarm all Disarm selected , all partitions armed and accessible to the user will be disarmed .
  • Page 63 INTEGRA SATEL Assuming that Partition 2 is disarmed, and Partitions 1, 3 and 4 are armed, the pattern shown on keypad display in the graphic mode may look like the one below: Example 3: ZONE BYPASSING - bypass Zone No. 4 named Entrance door and Zone No 49 named PIR secr.office; the user code: 38407.
  • Page 64 The status of all zones with breakdown into groups can be displayed by pressing . The INTEGRA 64 can display the status of all zones in two groups, and the INTEGRA 128 – in four groups. [ * ] End the function.
  • Page 65 Key functions and LED signaling on LCD keypad (details – see pages 8–12). ARMED SERVICE – blinking informs that TROUBLE – indicates detection of GROUP – zones or exp. bus the service mode is activated technical problem in the system – to check, steady light –...
  • Page 66: Istory Of The Manual Updates

    12. H ISTORY OF THE MANUAL UPDATES Given below is a description of changes as compared with the manual for the control panel with firmware in version v1.00. IRMWARE NTRODUCED CHANGES VERSION • Supplemented information on the ETHM-1 module (p. 6, 51). 2005-09 1.03 •...
  • Page 67 • Added information on defining the armed mode which is to be enabled by means of a timer (p. 31, 49). • Supplemented the diagram showing user functions menu (p. 35). • Added information on the option to assign key fobs to the users (p. 46). •...
  • Page 68 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.pl...