ABB VSN700 Product Manual page 30

Abb vsn700 data logger product manual
Table of Contents

Advertisement

Dimension
Height: 1.2" (3.05 cm)
Width: 5.35" (13.56 cm)
Length: 5.25" (13.34 cm)
Weight: 1 lbs. (0.454 kg)
Compliance
The data logger is compliant with both industrial and light industrial/commercial EMC standards for
both emission and immunity.
FCC Part 15 Class A; CISPR 22, EN 55022 Conducted and Radiated Emission; CISPR 24,
EN55024 Immunity
Safety
EN 60950-1, UL/CSA 60950-1 (External AC/DC Power Supply Adapter)
IP Network Services
Any network connected to the logger must allow traffic to pass on the following ports. Network
firewall rules (if present) must allow responses to the logger over existing TCP connections.
Direction
Service/Port
Out
ssh/22
Out
domain/53
Out
https/443
Out
dhcp/67, dhcp/68
Out
ntp/123
Network Hosts
The logger will connect to the following hosts. Some servers owned by ABB, and others are
customer or ISP servers. Servers listed as owned by "Customer IT/ISP" must be configured in the
logger using either DHCP or as static network information.
Host
platform.auroravision.net
gw1.auroravision.net
and/or
apt.fatspaniel.net
Site dependent
Site dependent
Protocol
Description
Tcp
For remote debugging by ABB service personnel, the data logger utilizes
encrypted SSH Remote Login Protocol. To allow service personnel
remote access to the data logger, this port has to be opened in any
firewall and forwarded to the data logger. (preferred)
Tcp/udp
The data logger must be able to resolve domain names, to ensure
scalability and dynamic changes on the Internet (DNS). (required)
Tcp
As an HTTP client, the data logger uses SSL/TLS protocol connections to
Aurora Vision® servers for secure communication. The logger uses this
port for all services, including data transmission, firmware upgrade,
configuration management, and remote command transmission.
(required)
Udp
If DHCP service is not available, static network information must be
assigned to the logger (preferred)
Udp
The logger uses this port for network time services (NTP). (preferred)
Purpose
Data, configuration
Logger firmware upgrade
DHCP (optional)
DNS
VSN700 Data Logger Product Manual
Port
TCP:443
TCP:443
UDP:67, UDP:68
UDP:53, TCP:53
- 30 -
Owner/Manager
ABB
ABB
Customer IT/ISP
Customer IT/ISP

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vsn700-01 seriesVsn700-03 seriesVsn700-05 series

Table of Contents