6-3. EHSC-VM6C, EHSC-VM6EC
Power supply
to Booster heater
~/N 230V 50Hz
L
N
(1)
(3)
ECB1
2 4
1
3
5
A1
BHCP
2
4
6
A2
BHC1
BHC2
1
3
5
A1
1
3
5
A1
2
4
6
A2
2
4
6
A2
BH1
BH2
2
2
2
BHT
BHF
2
1
2
CNBHT
3
(BLK)
1
2
CNBC
3
(GRY)
2
1
3
CNBH
2
5
(WHT)
7
1. Symbols used in wiring diagram are,
: terminal block.
2. Indoor unit and outdoor unit connecting wires have polarities,
make sure to match terminal numbers (S1, S2, S3) for correct
wirings,
3. Since the outdoor unit side electric wiring may change, be sure to
check the outdoor unit electric wiring diagram for service.
Table 1 Signal Inputs
Name Terminal block Connector
Item
IN1
TBI.1 13-14
Room thermostat 1 input
IN2
TBI.1 11-12
Flow switch 1 input
IN3
TBI.1 9-10
Flow switch 2 input (Zone1) Refer to SW3-2 in <Table 3 DIP Switch Functions>.
IN4
TBI.1 7-8
Demand control input
IN5
TBI.1 5-6
Outdoor thermostat input *1 Standard operation Heater operation/ Boiler operation *2
IN6
TBI.1 3-4
Room thermostat 2 input
IN7
TBI.1 1-2
Flow switch 3 input (Zone2) Refer to SW3-3 in <Table 3 DIP Switch Functions>.
IN8
TBI.3 1-2
Electric energy meter 1
IN9
TBI.3 3-4
Electric energy meter 2
IN10
TBI.3 5-6
Heat meter
*1. If using outdoor thermostat for controlling operation of heaters, the lifetime of the heaters and related parts may
be reduced.
*2. To turn on the boiler operation, use the main controller to select "Boiler" in "External input setting" screen in the
service menu.
Table 2 Outputs
Name Terminal block Connector
OUT1
TBO.1 1-2 CNP1 Water circulation pump 1 output (Space heating/cooling & DHW)
OUT2
TBO.1 3-4
Water circulation pump 2 output (Space heating/cooling for Zone1)
Water circulation pump 3 output (Space heating/cooling for Zone2) *1
OUT3
TBO.1 5-6
2-way valve 2b output *2
OUT4
TBO.2 4-6 CNV1 3-way valve (2-way valve) output
TBO.2 1-2
OUT5
Mixing valve output *1
TBO.2 2-3
OUT6
CNBH 1-3 Booster heater 1 output
OUT7
CNBH 5-7 Booster heater 2 output
OUT8
TBO.4 5-6
Cooling signal output
OUT9
TBO.4 3-4 CNIH Immersion heater output
OUT10 TBO.3 1-2
Boiler output
OUT11 TBO.3 3-4
Error output
OUT12 TBO.3 5-6
Defrost output
OUT13 TBO.4 1-2
2-way valve 2a output *2
OUT14
CNP4 Water circulation pump 4 output (DHW)
OUT15 TBO.3 7-8
Comp ON signal
Do not connect to the terminals that are indicated as "—" in the "Terminal block" field.
*1. For 2-zone temperature control.
*2. For 2-zone valve ON/OFF control.
OCH571
F1
CNPWM
(WHT)
1
3
F2
(WHT)
3
CNP1
TBO.1
(WHT)
X1
1
1
M
1~
2
MP1
3
M
X2
3
1~
M
2WV2b
1~
4
MP2
X3
5
M
TBO.1
1
1~
6
2
MP3
X14
3
1
1
M
4
3
1~
5
3
MP4
6
CNP4
(RED)
1
1
TBO.2
3
2
TBO.2
X5A
3
Close
1
4
M
N
Open
1~
2
5
X5B
6
MXV
3
1
X4
1
4
TBO.3
1
*1
5
2
5
5
3
6
CNV1
4
(WHT)
5
6
TBO.3
7
X10
1
Signal output
8
(Boiler)
2
X11
1
TBO.4
3
Signal output
2
(Error)
4
3
X12
Signal output
5
4
(Defrost)
5
6
X15
6
1
7
Signal output
3
(Comp ON)
8
TBO.4
1
1
CNBC
X13
1
(GRY)
CNIH
M
3
3
(ORN)
2
X9
2WV2a
3
1
1
4
3
CNBH
X8
Signal output
5
(WHT)
(Cooling)
6
7
1
3
CNBHT
(BLK)
CNBC
(GRY)
2 4 6 8 10 12 14
1
1 3 5 7 9 11 13
3
TBI.1
X6
1
3
X7
5
7
CNBH
(WHT)
: connector,
1
2
1
t
t
°
°
OFF (Open)
ON (Short)
Refer to SW2-1 in <Table 3 DIP Switch Functions>.
Refer to SW2-2 in <Table 3 DIP Switch Functions>.
Normal
Heat source OFF/ Boiler operation *2
Refer to SW3-1 in <Table 3 DIP Switch Functions>.
Refer to installation manual.
Item
<How to use TBO.1 to 4>
1
Connect them using either way as shown below.
2
4
Tool
6
Tool
CN01
Conductor
Conductor
Outline view
Top view
1
2
CN01
4
(WHT)
6
CNP1
(WHT)
F2
F1
6.3A 250V
10A 250V
1
CNP4
(RED)
SW5
1
CN3C
(BLU)
3
8
LED1
1
1
CNPWM
CNV1
SW4
(WHT)
(WHT)
3
6
1
CNRF
(WHT)
SW3
LED2
8
1
CN105
LED3
(RED)
SW2
8
CNIT
1
(BLU)
CNIH
(ORN)
SW1
1
CN22
(BLU)
2
CNBHT
8
(BLK)
CN108
LED4
CN1A
CNW5
CNW12
CN21
CN20
(WHT)
(WHT)
(RED)
(YLW)
(RED)
1
1
1
1
1
2
2
3
4
4
2
4
6
8
10
12
2 4 6 8 10 12 14
1 3 5 7 9 11 13
1
3
5
7
9
11
13
TBI.3
TBI.2
TBI.1
TBI.3
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
+
4
1
3
1
2
t
t
t
°
°
°
Symbol
TB1
Terminal block <Power supply, Outdoor unit>
ECB1
Earth leakage circuit breaker for booster heater
MP1
Water circulation pump 1(Space heating & DHW)
MP2
Water circulation pump 2 (Space heating for Zone1)(Local supply)
MP3
Water circulation pump 3 (Space heating for Zone2)(Local supply)
MP4
Water circulation pump 4 (DHW)(Local supply)
3WV(2WV1) 3-way valve (2-way valve 1)(Local supply)
2WV2a
2-way valve (For Zone 1)(Local supply)
2WV2b
2-way valve (For Zone 2)(Local supply)
MXV
Mixing valve (Local supply)
BHT
Thermostat for booster heater
BHF
Thermal fuse for booster heater
BH1
Booster heater 1
BH2
Booster heater 2
BHC1
Contactor for booster heater 1
BHC2
Contactor for booster heater 2
Symbol
BHCP
Contactor for booster heater protection
TH1
Thermistor (Room temp.)(Option)
TH2
Thermistor (Ref. liquid temp.)
THW1
Thermistor (Flow water temp.)
THW2
Thermistor (Return water temp.)
THW5
Thermistor (DHW tank water temp.)(Option)
THW6
Thermistor (Zone1 flow temp.)(Option)
THW7
Thermistor (Zone1 return temp.)(Option)
OFF
ON
THW8
Thermistor (Zone2 flow temp.)(Option)
OFF
ON
THW9
Thermistor (Zone2 return temp.)(Option)
OFF
ON
THWB1
Thermistor (Boiler flow temp.)(Option)
THWB2
Thermistor (Boiler return temp.)(Option)
OFF
ON
IN1
Room thermostat 1 (Local supply)
IN2
Flow switch 1 (Local supply)
Heating
DHW
IN3
Flow switch 2 (Local supply)
Close
Stop
IN4
Demand control (Local supply)
Open
IN5
Outdoor thermostat (Local supply)
OFF
ON
IN6
Room thermostat 2 (Local supply)
OFF
ON
IN7
Flow switch 3 (Local supply)
IN8
Electric energy meter 1 (Local supply)
OFF
ON
IN9
Electric energy meter 2 (Local supply)
OFF
ON
IN10
Heat meter (Local supply)
OFF
ON
FLOW TEMP. CONTROLLER (FTC5)
Normal
Error
TBO.1−4 Terminal block <Outputs>
TBI.1−3 Terminal block <Signal Inputs, Thermistor>
Normal Defrost
F1
Fuse (T10AL250V)
OFF
ON
F2
Fuse (T6.3AL250V)
OFF
ON
SW1−5 DIP switch *See Table 3
OFF
ON
X1−15
Relay
LED1
Power supply (FTC5)
LED2
Power supply (Main controller)
LED3
Communication (FTC5-Outdoor unit)
LED4
Reading or writing data to SD card
CNPWM Pump speed control signal for MP1
CN108
SD card connector
12
Indoor unit powered
Indoor unit powered
by independent source
via outdoor unit
To outdoor
To outdoor
Power supply
unit
unit
~/N 230V 50Hz
L
N
S1
S2
S3
TB1
L
N
S1
S2
S3
TB1
BLK
BLK
BLK
BLK
1
1
2
2
CN01
CN01
4
(WHT)
(WHT)
4
6
6
BRN
BRN
1
1
CN3C
CN3C
ORN
ORN
(BLU)
(BLU)
3
3
Wireless receiver
(Option)
WiFi adapter
(Option)
*1
3WV
2WV1
4 5 6
4 5 6
TBO.2
TBO.2
M
M
1~
1~
3WV
2WV1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
2
3
4
5
6
7
8
9
10
+
+
CN22
(BLU)
1
2
t
°
t
°
t
°
t
°
Name
Name
11
12
13
14
t
°
t
°

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents