5) Blurred image
Defective area
Paper
Bedewed scanner
Drum
Ozone exhaust
December 2005 © TOSHIBA TEC
Fig. 5-5
Step
Check items
1
Is the paper in the drawer damp?
2
Is the scanner bedewed?
3
Is the drum surface wet or dirty?
4
Is the exhaust fan operating prop-
erly?
5
Is the ozone filter stained or dam-
aged?
5 - 23
Prescription
Change paper. Avoid storing paper in
damp place.
Clean the scanner.
Wipe the drum with a piece of dry
cloth.
*
Do not use alcohol or other
organic solvents.
Check the connection of connector.
Replace the ozone exhaust fan.
Replace the ozone filter.
e-STUDIO163/203 TROUBLESHOOTING