Q43: Installer Code (4 Digits) - 2gig Technologies Go!Control Panel Installation & Programming Manual

Wireless security system
Hide thumbs Also See for Go!Control Panel:
Table of Contents

Advertisement

Go!Control Wireless Security System  |  Installation and Programming Guide
Q43: Installer Code (4 Digits)
DEFAULT: 1561
The installer code is a unique code that installation 
technicians use to access the Installer Toolbox on the 
Control Panel.
The default installer code is 1561.
To change the installer code, enter a new four (4)‐
digit code.
IMPORTANT: If you change the installer code, always write 
it down so you can access the system later.
NOTE: The installer code must be unique from the master 
user code and all other user codes.
Q44: Lock Installer Programming (0-2)
DEFAULT: (0) Disabled 
The installer programming lockout feature is provided to 
prevent takeovers. The Control Panel can be set to limit an 
installer's access to programming questions after a period 
of 48 hours. The 48‐Hour Lockout timer starts when the 
installer exits System Configuration mode. 
Three (3) options are available:
Unlimited full access to programming (no lockout)
Limited access to programming after 48 hours
No access to programming after 48 hours
The default setting (0) Disabled selects unlimited full access 
to programming (no lockout).
To deny access to programming after 48 hours, select (1) No 
Access to Programming.
If you select (2) Limited Access to Programming the installer 
will be able to view, but not change the following attributes 
after the system has run for 48 hours, the Central Station 
phone number, Central Station account number, lock 
installer programming, download ID, and default lockout 
fields.
After the 48 hour lockout timer has locked out the system, 
the timer can be reset through the cell radio or PC 
download by remotely setting this question to (0) or (2). 
Setting the option to (0) or (2) will restart the 48 hour 
lockout timer.
Q45: Lock Default Programming (0-2)
DEFAULT: (0) Default All 
The Control Panel may be able to be hard reset (or soft 
reset from the Installer Toolbox) to its factory default values 
depending on the value entered for this programming 
question.
The Control Panel is hard reset by pressing and holding the 
 and 
 buttons while applying power to the Control 
Panel.
The default lockout feature is provided to prevent 
takeovers. Three options are available: allow default of all 
options, allow default of some but not all options, not allow 
default of any options.
The default setting of (0) Default All allows resetting 
the Control Panel to all its factory defaults.
To allow resetting the Control Panel to all its factory 
defaults except the Central Station phone number, 
Central Station account number, lock installer 
programming, download ID, and default lockout 
60
    Copyright ©  2014 Linear LLC
fields, select (1) Default All Except CSID, Account/
Phone, Lockouts.
To deny hard and soft resetting of the Control 
Panel, select (2) Default None.
If option 1 or 2 is selected, the option takes effect after the 
system runs for 48 hours. This allows the installer to go back 
and make changes if required.
Q46: Trouble Doesn't Sound at Night (0-
1)
DEFAULT: (1) Enabled
NOTE: For UL 985: Household Fire Warning System Units 
installations, this setting must be set to (0) Disabled
The Control Panel will sound trouble beeps caused by AC 
loss, system low battery, sensor low battery or RF 
supervision, failure to communicate, Control Panel tamper 
while disarmed, and cell radio faults.
To prevent annoying the subscriber, the system can be set 
to suppress trouble beeps from sounding from 10 
. The trouble alerts are still displayed and immediately 
AM
reported to the Central Station, and can be acknowledged, 
but they won't sound beeps until after 9 
If the trouble condition(s) self‐clear or are acknowledged 
before 9 
, no trouble beeps sound after 9 
AM
conditions are still recorded in the event log).
The default setting (1) Enabled suppresses trouble 
beeps from 10 
 to 9 
PM
To allow trouble beeps at any time, select (0) 
Disabled..
Q47: Trouble Resound After Hold Off (0-7)
DEFAULT: (0) Disabled 
Fire and CO sensors are required to re‐sound trouble beeps 
every four hours until the trouble is resolved, even if the 
trouble is acknowledged at the Control Panel. The Control 
Panel can be set to delay re‐sounding these types of trouble 
beeps for 1‐7 days.
NOTE: This feature is not allowed in UL 985 installations. 
The setting must be (0) Disabled in this grade of 
installation.
The default setting (0) Disabled allows trouble 
beeps for CO and fire sensors to re‐sound every 
four (4) hours after being acknowledged
To delay re‐sounding trouble beeps for CO and Fire 
sensors, select (1‐7) days
 to 9 
PM
.
AM
 (the 
AM
AM