Go!Control Wireless Security System | Installation and Programming Guide
Q43: Installer Code (4 Digits)
DEFAULT: 1561
The installer code is a unique code that installation
technicians use to access the Installer Toolbox on the
Control Panel.
•
The default installer code is 1561.
•
To change the installer code, enter a new four (4)‐
digit code.
IMPORTANT: If you change the installer code, always write
it down so you can access the system later.
NOTE: The installer code must be unique from the master
user code and all other user codes.
Q44: Lock Installer Programming (0-2)
DEFAULT: (0) Disabled
The installer programming lockout feature is provided to
prevent takeovers. The Control Panel can be set to limit an
installer's access to programming questions after a period
of 48 hours. The 48‐Hour Lockout timer starts when the
installer exits System Configuration mode.
Three (3) options are available:
•
Unlimited full access to programming (no lockout)
•
Limited access to programming after 48 hours
•
No access to programming after 48 hours
The default setting (0) Disabled selects unlimited full access
to programming (no lockout).
To deny access to programming after 48 hours, select (1) No
Access to Programming.
If you select (2) Limited Access to Programming the installer
will be able to view, but not change the following attributes
after the system has run for 48 hours, the Central Station
phone number, Central Station account number, lock
installer programming, download ID, and default lockout
fields.
After the 48 hour lockout timer has locked out the system,
the timer can be reset through the cell radio or PC
download by remotely setting this question to (0) or (2).
Setting the option to (0) or (2) will restart the 48 hour
lockout timer.
Q45: Lock Default Programming (0-2)
DEFAULT: (0) Default All
The Control Panel may be able to be hard reset (or soft
reset from the Installer Toolbox) to its factory default values
depending on the value entered for this programming
question.
The Control Panel is hard reset by pressing and holding the
and
buttons while applying power to the Control
Panel.
The default lockout feature is provided to prevent
takeovers. Three options are available: allow default of all
options, allow default of some but not all options, not allow
default of any options.
•
The default setting of (0) Default All allows resetting
the Control Panel to all its factory defaults.
•
To allow resetting the Control Panel to all its factory
defaults except the Central Station phone number,
Central Station account number, lock installer
programming, download ID, and default lockout
60
Copyright © 2014 Linear LLC
fields, select (1) Default All Except CSID, Account/
Phone, Lockouts.
•
To deny hard and soft resetting of the Control
Panel, select (2) Default None.
If option 1 or 2 is selected, the option takes effect after the
system runs for 48 hours. This allows the installer to go back
and make changes if required.
Q46: Trouble Doesn't Sound at Night (0-
1)
DEFAULT: (1) Enabled
NOTE: For UL 985: Household Fire Warning System Units
installations, this setting must be set to (0) Disabled
The Control Panel will sound trouble beeps caused by AC
loss, system low battery, sensor low battery or RF
supervision, failure to communicate, Control Panel tamper
while disarmed, and cell radio faults.
To prevent annoying the subscriber, the system can be set
to suppress trouble beeps from sounding from 10
. The trouble alerts are still displayed and immediately
AM
reported to the Central Station, and can be acknowledged,
but they won't sound beeps until after 9
If the trouble condition(s) self‐clear or are acknowledged
before 9
, no trouble beeps sound after 9
AM
conditions are still recorded in the event log).
•
The default setting (1) Enabled suppresses trouble
beeps from 10
to 9
PM
•
To allow trouble beeps at any time, select (0)
Disabled..
Q47: Trouble Resound After Hold Off (0-7)
DEFAULT: (0) Disabled
Fire and CO sensors are required to re‐sound trouble beeps
every four hours until the trouble is resolved, even if the
trouble is acknowledged at the Control Panel. The Control
Panel can be set to delay re‐sounding these types of trouble
beeps for 1‐7 days.
NOTE: This feature is not allowed in UL 985 installations.
The setting must be (0) Disabled in this grade of
installation.
•
The default setting (0) Disabled allows trouble
beeps for CO and fire sensors to re‐sound every
four (4) hours after being acknowledged
•
To delay re‐sounding trouble beeps for CO and Fire
sensors, select (1‐7) days
to 9
PM
.
AM
(the
AM
AM
Need help?