Premier 412/816/832 Installation Manual
Service Faults
The response to a Service Fault condition is programmed by
the installer but is normally limited to the keypad buzzer. To
silence the Service Fault alarm, enter your Access code.
A flashing Service light indicates a new fault condition. The
alarm system cannot be armed whilst a new fault exists. The
Service light will remain flashing until the new fault is
acknowledged, after which it will revert to a steady yellow
and the alarm system can be armed. The Service light will
remain steady until all faults have been cleared.
After a new Service Fault has been acknowledged the
Service light will revert to steady yellow and the alarm
system can be armed. The Service light will remain steady
yellow until all faults have been cleared.
AC Fail and Telephone Line Fault can each have a delay
programmed. The Service light will turn steady yellow
immediately on either of these faults but no Service Fault
Alarm (transmission or audible alarm) will occur unless the
delay expires.
!
If your installer has disabled AC fail acknowledgement
the Service light will flash "rapidly" during an AC fail
condition. The system can be armed without requiring
acknowledgement of this fault.
Acknowledging a New Service Fault
" New service faults can be acknowledged as follows:
Enter Access code ????
1
Zones
1
2
3
4
5
6
7
8
Alarm
Service
Press N2
2
Zones
1
2
3
4
5
6
7
8
Alarm
Service
The keypad will display all Service Faults.
N
R
3
Press
or
to acknowledge the fault and return to
the normal disarmed state.
View Service Faults
" Standing faults can be viewed as follows:
Press the , key followed by the # key.
1.
2.
The keypad will display any Service Faults (see
tables).
On completion press the , key.
3.
INS159-7
YES to Arm?
Armed
MENU for Options
Ready
System Faults:-
Armed
Press Menu/Reset
Ready
Line Fault
Press Menu/Reset
Service Faults Displayed on LED Keypads
Light
Fault Condition
1
AC Fail
2
Telephone Line Fault
3
2-Wire Smoke Alarm
Box Tamper & Auxiliary Input:
Press % to view type, lights 1 - 5 indicate:
4
1 = Box Tamper
2 = Auxiliary Tamper
3 = Auxiliary PA
5
Date or Time Lost
Zone Tamper/Trouble
6
Press ' to view zone number
Keypad Tamper/Removed
7
Press ( to view keypad number
Equipment Faults
Press ) to view fault type, lights 1 - 8 indicate:
1 = Output 1 Fault
2 = Output 2 Fault
3 = Siren/Bell Fault
8
4 = 2-Wire Smoke Sensor Fault
5 = Auxiliary Fuse Failed
6 = Battery Fault
7 = Service Timer/Zone Soak Test Failed
8 = Communication Fault
Service Faults Displayed on LCD Keypads
LCD
!"#$%&'#
AC Fail
Telephone Line Fault
(&)*#$%+',#
-./0*#!'%1.#2345# 2-Wire Smoke Alarm
6/78!+7#9%.:*1#
Box Tamper
!+7#9%.:*1#
Auxiliary Tamper (Aux Input)
!+7&'&1;#9%.:*1
Auxiliary Tamper (UK Bell Module)
6*''#9%.:*1#
Bell Tamper (UK Bell Module)
!+7#<!#!'%1.#
Auxiliary PA (Aux Input)
Date or Time Lost
=%,*89&.*#(/>>#
9%.:*1#?/)*#@#AB# Zone Tamper/Trouble
9%.:*1#C*;:%D@#B# Keypad Tamper/Removed
E+,:+,#B#$%+',#
Output 1 Fault
E+,:+,#3#$%+',#
Output 2 Fault
-&1*)#$%+',#
Siren/Bell Fault
-./0*#-*)F#$%+',# 2-Wire Smoke Sensor Fault
Auxiliary Fuse Failed
!+7F#$+>*#$%+',#
6%,,*1;#$%+',#
Battery Fault
-*1G&H*#I*J+&1*D
Service Timer/Zone Soak Test Failed
"/.>#$%&'*D#
Communication Fault
Operating the Alarm System
4 = Auxiliary Tamper *
5 = Bell Tamper *
* = UK Bell Module
Fault Condition
71