Sharp AY-ZP35PR Service Manual page 27

Air/air heat pump
Table of Contents

Advertisement

AY-ZP35PR
2. Outdoor unit
Item
Compressor cham-
Cooling
ber thermistor
Dehumidifying
(TH1)
Heating
Heat exchanger
Cooling
thermistor (TH2)
Dehumidifying
Heating
Outside air temper-
Auto
ature thermistor
(TH3)
Cooling
Dehumidifying
Heating
Suction pipe ther-
Cooling
mistor (TH4)
Dehumidifying
Heating
2-way valve ther-
Cooling
mistor (TH5)
Dehumidifying
Heating
Mode
Control operation When resistance
Expansion valve
control and com-
pressor protection
Outdoor unit heat
exchanger over-
heat prevention
Expansion valve
control
Defrosting
Operation mode
judgment
Operation not
affected
Rating control
Defrosting
Expansion valve
control
Expansion valve
control
Expansion valve
control
Operation not
affected
Short-circuit
is low (tempera-
ture judged higher
than actual)
Compressor oper-
Compressor high
ates, but room does
temperature error
not become cool or
indication.
warm (expansion
valve is open).
Compressor oper-
Outdoor unit ther-
ates at low speed
mistor short-circuit
or stops.
error indication.
Defrosting opera-
Outdoor unit ther-
tion is not activated
mistor short-circuit
as needed, and
error indication.
frost accumulates
on outdoor unit
(expansion valve is
closed).
Cooling mode is
Outdoor unit ther-
activated even if
mistor short-circuit
room temperature
error indication.
is low.
Normal operation.
Outdoor unit ther-
mistor short-circuit
error indication.
Defrosting opera-
Outdoor unit ther-
tion is activated
mistor short-circuit
unnecessarily.
error indication.
Compressor oper-
Outdoor unit ther-
ates, but room does
mistor short-circuit
not become cool
error indication.
(expansion valve is
open).
Compressor oper-
Outdoor unit ther-
ates, but room does
mistor short-circuit
not become warm
error indication.
(expansion valve is
open).
Frost accumulates
Outdoor unit ther-
on indoor unit evap-
mistor short-circuit
orator and room
error indication.
does not become
cool (expansion
valve is closed).
Normal operation.
Outdoor unit ther-
mistor short-circuit
error indication.
3-4
When resistance
Open-circuit
is high (tempera-
ture judged lower
than actual)
Layer short-circuit
Outdoor unit ther-
or open-circuit may
mistor open-circuit
result in compres-
error indication.
sor in normal oper-
ation.
Normal operation.
Outdoor unit ther-
mistor open-circuit
error indication.
Defrosting opera-
Outdoor unit ther-
tion is activated
mistor open-circuit
unnecessarily, and
error indication.
room does not
become warm
(expansion valve is
open).
Heating mode is
Outdoor unit ther-
activated even if
mistor open-circuit
room temperature
error indication.
is high.
Normal operation.
Outdoor unit ther-
mistor open-circuit
error indication.
Defrosting opera-
Outdoor unit ther-
tion is not activated,
mistor open-circuit
and frost accumu-
error indication.
lates on outdoor
unit.
Frost accumulates
Outdoor unit ther-
on evaporator inlet
mistor open-circuit
section, and room
error indication.
does not become
cool (expansion
valve is closed).
Frost accumulates
Outdoor unit ther-
on expansion valve
mistor open-circuit
outlet section, and
error indication.
room does not
become warm
(expansion valve is
closed).
Compressor oper-
Outdoor unit ther-
ates, but room does
mistor open-circuit
not become cool
error indication.
(expansion valve is
open).
Normal operation.
Outdoor unit ther-
mistor open-circuit
error indication.