Mitsubishi Electric FR-F740-00023 Instruction Manual page 71

F700 series
Hide thumbs Also See for FR-F740-00023:
Table of Contents

Advertisement

Parameter list
Function Parameters
553
PID deviation limit
554
PID signal operation selection
555
Current average time
556
Data output mask time
Current average value monitor signal
557
output reference current
563
Energization time carrying-over times
564
Operating time carrying-over times
570
Multiple rating setting
571
Holding time at a start
573
4mA input check selection
575
Output interruption detection time
576
Output interruption detection level
577
Output interruption cancel level
578
Auxiliary motor operation selection
579
Motor connection function selection
580
MC switching interlock time
581
Start waiting time
Auxiliary motor connection-time
582
deceleration time
Auxiliary motor disconnection-time
583
acceleration time
584
Auxiliary motor 1 starting frequency
585
Auxiliary motor 2 starting frequency
586
Auxiliary motor 3 starting frequency
587
Auxiliary motor 1 stopping frequency
588
Auxiliary motor 2 stopping frequency
589
Auxiliary motor 3 stopping frequency
590
Auxiliary motor start detection time
591
Auxiliary motor stop detection time
592
Traverse function selection
593
Maximum amplitude amount
Amplitude compensation amount
594
during deceleration
Amplitude compensation amount
595
during acceleration
596
Amplitude acceleration time
597
Amplitude deceleration time
611
Acceleration time at a restart
653
Speed smoothing control
654
Speed smoothing cutoff frequency
Pulse increment setting for output
799
power
867
AM output filter
869
Current output filter
62
Name
0 to 100.0%, 9999
0 to 3, 10 to 13
0.1 to 1.0s
0.0 to 20.0s
0 to 500A/0 to 3600A
(0 to 65535)
(0 to 65535)
0, 1
0.0 to 10.0s, 9999
1, 9999
0 to 3600s, 9999
0 to 400Hz
900 to 1100%
0 to 3
0 to 3
0 to 100s
0 to 100s
0 to 3600/360s, 9999
0 to 3600/360s, 9999
0 to 400Hz
0 to 400Hz
0 to 400Hz
0 to 400Hz
0 to 400Hz
0 to 400Hz
0 to 3600s
0 to 3600s
0, 1, 2
0 to 25%
0 to 50%
0 to 50%
0.1 to 3600s
0.1 to 3600s
0 to 3600s, 9999
0 to 200%
0 to 120Hz
0.1kWh, 1kWh, 10kWh,
100kWh, 1000kWh
0 to 5s
0 to 5s
Minimum
Setting Range
Setting
Increments
0.1%
0.1s
0.1s
0.01/0.1A
0.1s
0.1s
0.01Hz
0.1%
0.1s
0.1s
0.1/0.01s
0.1/0.01s
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.1s
0.1s
0.1%
0.1%
0.1%
0.1s
0.1s
0.1s
0.1%
0.01Hz
0.1
0.01s
0.01s
Refer
Initial
to
Value
Page
9999
219
1
0
219
1s
255
0s
255
Rated
inverter
255
current
1
0
126
1
0
126
1
0
75
9999
92
1
9999
167
1s
219
0Hz
219
1000%
219
1
0
236
1
0
236
1s
236
1s
236
1s
236
1s
236
50Hz
236
50Hz
236
50Hz
236
0Hz
236
0Hz
236
0Hz
236
5s
236
5s
236
1
0
246
10%
246
10%
246
10%
246
5s
246
5s
246
5/15s
136
0
154
20Hz
154
1kWh
124
0.01s
131
0.02s
131
Customer
Setting

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents