User Control Pcb Replacement - Ideal Boilers i 24 Installation & Servicing Instructions Manual

Combination boilers
Table of Contents

Advertisement

51 UsER CONTROL pCb REpLaCEMENT

Note. Fit the earth strap provided with the PCB
to your wrist and a suitable earth on the boiler
chassis.
1. Refer to Frame 40.
2. Remove the main PCB, refer to Frame 50.
3. Unclip the PCB and lift to clear the mounting
posts.
4. Fit the new PCB ensuring the 3 potentiometer
spindles line up with the control knobs which
must be in a vertical position.
5. Reassemble in reverse order.
6. Check operation of the boiler. Refer to Frames
29 & 30.
4
PCB
Control Knobs (to be in vertical position)
OFF
RESET
MODE
52 REpLaCINg ThE MEChaNICaL TIMER
1. Refer to Frame 40.
2. Swing the boiler lower front panel into the service
position. Refer to Frame 34.
3. Remove the 4 fixing screws.
4. Disconnect the 4 push on connectors.
5. Remove programmer.
6. Re-fit 4 push on connectors to new programmer.
7. Fit programmer and retain with 4 screws previously
removed.
8. Replace the lower front panel.
9. Check operation of the boiler. Refer to Frames 29 &
30.
note. To program refer to user guide at rear of this
book.
i combi -
Installation and Servicing
SERVICING
i
24
E
MAX
MIN
PRE
MIN
MAX
HEAT
STATUS
BURNER
PREHEAT
3
Potentiometer spindle
4
2
43

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the i 24 and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF