USER GUIDE
IDEAL INSTINCT
24 30 35
When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Boilers.
For the very latest copy of literature for specification and maintenance practices visit our website www.idealboilers.com
where you can download the relevant information in PDF format.
July 2018
UIN 212456 A05

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the INSTINCT 24 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ideal Boilers INSTINCT 24

  • Page 1 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Boilers.
  • Page 2: Table Of Contents

    INTRODUCTION CONTENTS The Ideal INSTINCT is a combination boiler providing both central heating and instantaneous domestic hot water. Featuring full se- 1. Introduction .............. 2 quence automatic ignition and fan assisted combustion. Due to the high efficiency of the boiler, condensate is produced from Safety .................
  • Page 3: Boiler Operation

    BOILER OPERATION status burner Legend A. Mode Knob reset preheat B. Domestic Hot Water / Preheat Knob preheat mode C. Central Heating Temperature Knob D. Boiler Status E. Burner ‘on’ Indicator F. Domestic Hot Water Preheat on / off indicator G.
  • Page 4: Efficient Heating System Operation

    3. SYSTEM WATER PRESSURE EFFICIENT HEATING SYSTEM OPERATION The boiler is a high efficiency, condensing appliance which will The system pressure gauge (H - see automatically adjust its output to match the demand for heat. page 3) indicates the central heating Therefore gas consumption is reduced as the heat demand is system pressure.
  • Page 5: General Information

    GENERAL INFORMATION MECHANICAL 24 HOUR TIMER BOILER PUMP The boiler pump will operate briefly as a self-check once every 24 Align current hours, regardless of system demand. time to arrow Timer Control MINIMUM CLEARANCES Permanently ON Clearance of 165mm (6 ”) above, 100mm (4”) below, 2.5mm ( ”) Time &...
  • Page 6: Points For The Boiler User

    POINTS FOR THE BOILER USER Note. In line with our current warranty policy we would ask that you check through the following guide to identify any problems external to the boiler prior to requesting a service engineers visit. Should the problem be found to be other than with the appliance we reserve the right to levy a charge for the visit, or for any pre-arranged visit where access is not gained by the engineer.
  • Page 7: Normal Operation Display Codes

    NORMAL OPERATION DISPLAY CODES DESCRIPTION DISPLAY CODE ON BOILER The boiler is in standby mode awaiting either a central heating call or hot water demand. The boiler has a call for central heating but the appliance has reached the desired temperature set on the boiler.
  • Page 8: Fault Codes

    DISPLAY CODE ON BOILER BCC Activation Fault Reset the appliance - if the boiler fails to operate then please contact Ideal Boilers (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

This manual is also suitable for: