Do you have a question about the Ruby and is the answer not in the manual?
Questions and answers
David Grieves
March 1, 2025
What is the correct placing of the coals in a Ruby hole in the wall fire please
1 comments:
Mr. Anderson
March 1, 2025
The coals should be placed as follows in a Crystal Fires Ruby hole-in-the-wall fire:
1. Place the front fibre as far towards the back fibre as possible without covering the burner. 2. Ensure that if the flames are turned on, the front pebbles do not obstruct the flame burner. 3. Arrange two random fuel pieces on the two sides as shown in the instructions. 4. Position five pieces between the two side pieces as indicated. 5. Place the final three pieces centrally as shown in the instructions. 6. Arrange four additional random pieces in the specified positions.
This setup ensures proper flame distribution and safety.
Decorative fuel effect gas fire, this appliance is cat i2h for use with natural gas only g20 at 20mbar in g.b. and i.e. (24 pages)
Summary of Contents for crystal fires Ruby
Page 1
BECHERS DRIVE AINTREE RACECOURSE BUSINESS PARK AINTREE LIVERPOOL L9 5AY RUBY DECORATIVE FUEL EFFECT GAS FIRE THIS APPLIANCE IS CAT I FOR USE WITH NATURAL GAS ONLY G20 AT 20mbar IN G.B. AND I.E. INSTALLATION & SERVICING BOOK ISSUE 2...
Page 2
SIZES INCLUDING STANDARD TRIM 270mm 180mm 383mm width of curve 600mm 550mm 180mm 465mm SIZES INCLUDING TRIM RADIANT BOX PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE YOU START INSTALLING THE APPLIANCE. KEEP THIS BOOKLET HANDY FOR FUTURE REFERENCE ISSUE 2...
Page 3
TECHNICAL DATA GAS TYPE: NATURAL GAS GAS PRESSURE: 20mbar CONNECTION 8mm TUBE INJECTOR manual control: CAT 82/420 BRAY INJECTOR remote control: CAT 82/400 BRAY HEAT INPUT 6.5kW HIGH 4.1kW LOW CAT 1 DATA BADGE ON FRONT BOTTOM SECTION OF APPLIANCE IMPORTANT NOTES THIS APPLIANCE IS FITTED WITH AN ATMOSPHERE SENSING DEVICE AND CAN ONLY BE FITTED IN CONJUNCTION WITH THE FOLLOWING...
Page 4
WARNING THIS APPLIANCE HAS A NAKED FLAME, AS WITH ALL SUCH FIRES IT IS RECOMMENDED THAT A FIREGUARD SHOULD BE USED FOR THE PROTECTION OF CHILDREN, THE ELDERLY AND INFIRM. FIRE GUARDS SHOULD CONFORM TO BS8423 2002 (FIREGUARDS FOR FIRES AND HEATING APPLIANCES FOR DOMESTIC USE-SPECIFICATION) INSTALLATION REQUIREMENTS PRE CAST FLUES...
Page 5
CONVENTIONAL CHIMNEY A CONVENTIONAL BRICK OR STONE CHIMNEY AS USED FOR SOLID FUEL APPLIANCE WITH A MINIMUM EFFECTIVE CROSS SECTIONAL DIMENSION OF 225*225mm, WITH A MINIMUM OF 3 METERS EFFECTIVE HEIGHT. A LINED FLUE WITH A MINIMUM DIAMETER OF 125mm WITH THE FIREPLACE COMPONENTS CONFORMING TO BS 1251 A BUILDERS OPENING A MINIMUM OF 560mm HIGH AND 400mm WIDE WITH A MINIMUM DEPTH OF 230mm TO ALLOW SUFFICIENT VOLUME OF...
Page 6
THE RELEVANT BRITISH STANDARDS MUST BE FOLLOWED BS 5871 :PART 3 BS 5440: PART 1 AND 2 BS 6891 BS 8303 BS 1251 AND I.S 813 FOR IRELAND A BRICK CHAMBER TO THE SIZES IN FIG 2 IN AN EXISTING BRICK OR STONE CHIMNEY A 125mm MINIMUM DIAMETER FLUE LINER CONFORMING TO BS715 MAY BE USED, PROVIDING IT IS SEALED AT THE TOP AND BOTTOM OF THE EXISTING BRICK OR STONE CHIMNEY.
Page 7
INSTALLATION REQUIREMENTS 5”(125mm) FLUE PIPE AND STARTER BOX A DOUBLE WALLED SELKIRK RECESSED FLUE BOX BUILT TO THE REQUIRMENTS OF BS 715 WITH AN INSULATED FLUE HAVING A MINIMUM DIAMETER OF 125mm(5”) AND A MINIMUM EFFECTIVE OVERALL HEIGHT OF 3 METRES (10FT) 143mm 560mm 610mm...
Page 8
A NON COMBUSTIBLE HEARTH MUST BE PROVIDED BENEATH THE APPLIANCE WITHIN THE FIREPLACE OPENING. A FIRE RESISTANT HEARTH MUST ALSO BE PROVIDED SYMMETRICALLY DISPOSED ABOUT THE FIREPLACE OPENING A MINIMUM THICKNESS OF 12mm WITH THE PERIMETER 50mm ABOVE THE FLOOR LEVEL THE WIDTH MUST EXTEND A MINIMUM OF 150mm EITHER SIDE OF THE FIREPLACE OPENING AND A DEPTH OF 300mm FROM THE FUEL BED ANY COMBUSTIBLE MATERIAL MUST BE REMOVED ABOVE THE...
CHECKING GAS PRESSURE AND SOUNDNESS REMOVE THE PRESSURE TEST POINT SCREW FROM THE INLET ELBOW AND CONNECT PRESSURE GAUGE. TURN ON GAS TO APPLIANCE. ROTATE THE CONTROL TO THE IGNITION POSITION AND PUSH IN TO ALLOW THE AIR IN THE PIPEWORK TO BE PURGED. PUSH IN PIEZO IGNITION SWITCH CHECK THAT THE ELECTRODE IS SPARKING.
Page 10
RUBY RANDOM PEBBLE LAYOUT SIX RANDOM PEBBLES FIT FLUSH ON TOP OF FRONT FIBRE, PUSHED AS FAR TOWARDS THE BACK FIBRE BUT NOT OVER THE BURNER. IF THE FLAMES WAS TURNED ON NOW THE FRONT PEBBLES WOULD NOT IMPINGE THE...
Page 11
TEST FOR SPILLAGE CHECK FOR SATISFACTORY CLEARANCE OF COMBUSTION PRODUCTS CLOSE ALL DOORS AND WINDOWS IN THE ROOMS CONTAINING THE FIRE. TURN ON GAS FIRE AND SET THE CONTROL TO HIGH LEAVE THE FIRE BURNING FOR FIVE MINUTES AND INSERT A LIGHTED SMOKE MATCH ON A VERTICAL PLANE 50 mm DIRECTLY UNDER FRONT EDGE OF CANOPY AND 50mm FROM EITHER SIDE OF THE OPENING...
Page 12
SERVICING NOTES GENERAL NOTES. SERVICING SHOULD BE CARRIED OUT ANNUALLY BY A COMPETENT PERSON SUCH AS A CORGI REGISTERED PERSON IN ACCORDANCE WITH THE RELEVANT REGULATIONS, TO ENSURE THE SAFE AND CORRECT OPERATION OF THE APPLIANCE BEFORE COMMENING ANY SERVICE OR REPLACEMENT OF PARTS TURN OFF GAS SUPPLY TO FIRE AFTER SERVICING CHECK FOR GAS SOUNDNESS AT LEAST ONCE A YEAR CHECK FOR DEBRIS...
Page 13
CERAMICS SHOULD BE CLEANED BY SHAKING ANY DEBRIS NO BRUSHING OR VACUUMING SHOULD BE PERFORMED . INSTALLER SPARE PARTS FUEL BED RUBY001 MAIN MATRIX RUBY002 FRONT FIBRE RUBY 003 INSTUCTIONS RUBY 004 TRIM RUBY 005 ODS COMPLETE RUBY 006 GAS VALVE...
Page 14
BECHERS DRIVE AINTREE RACECOURSE BUSINESS PARK AINTREE LIVERPOOL L9 5AY RUBY DECORATIVE FUEL EFFECT GAS FIRE THIS APPLIANCE IS CAT I FOR USE WITH NATURAL GAS ONLY G20 AT 20mbar IN G.B. AND I.E. USERS INSTUCTIONS ISSUE 2...
Page 15
USERS INSTRUCTIONS FOR RUBY GAS APPLIANCE YOUR RUBY GAS APPLIANCE IS A DECORATIVE LIVE FUEL EFFECT GAS FIRE ,DUE TO ITS NEWNESS THE FIRE MAY GIVE OFF SLIGHT SMELL FOR A SHORT PERIOD AFTER INSTALLATION .THIS IS QUITE NORMAL AND WILL DISAPPEAR AFTER A FEW HOURS OF OPERATION.
Page 16
JET CAT82/480 BRAY JET CAT82/420 BRAY PILOT RUBY DECORATIVE INSERT CRYSTAL FIRES 7 D BECHERS DRIVE L9 5AY THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE RULES IN FORCE AND USED ONLY IN A SUFFICIENTLY VENTILATED SPACE .CONSULT INSTRUCTIONS BEFORE...
Page 17
RUBY GAS FIRE LIGHTING WITH TAPER TO LIGHT WITH TAPER ,PUSH "D" "D" LIGHTED TAPER AS SHOWN "D" "D" WHILST FOLLOWING THE OPERATING INSTRUCTIONS "B" "B" "D" "D" "D" "D" "D" "D" "D" TAPER FUEL BED LAYOUT PERIODICALLY SMALL DEPOSITS OF SOOT MAY GATHER...
Page 18
RUBY RANDOM PEBBLE LAYOUT SIX RANDOM PEBBLES FIT FLUSH ON TOP OF FRONT FIBRE, PUSHED AS FAR TOWARDS THE BACK FIBRE BUT NOT OVER THE BURNER. IF THE FLAMES WAS TURNED ON NOW THE FRONT PEBBLES WOULD NOT IMPINGE THE...
Need help?
Do you have a question about the Ruby and is the answer not in the manual?
Questions and answers
What is the correct placing of the coals in a Ruby hole in the wall fire please
The coals should be placed as follows in a Crystal Fires Ruby hole-in-the-wall fire:
1. Place the front fibre as far towards the back fibre as possible without covering the burner.
2. Ensure that if the flames are turned on, the front pebbles do not obstruct the flame burner.
3. Arrange two random fuel pieces on the two sides as shown in the instructions.
4. Position five pieces between the two side pieces as indicated.
5. Place the final three pieces centrally as shown in the instructions.
6. Arrange four additional random pieces in the specified positions.
This setup ensures proper flame distribution and safety.
This answer is automatically generated