crystal fires jewel Installation & Servicing

Decorative fuel effect gas fire

Advertisement

1 VALENTINES BUILDINGS
BECHERS DRIVE
AINTREE RACECOURSE
BUSINESS PARK
AINTREE
LIVERPOOL
L9 5AY
JEWEL
DECORATIVE FUEL EFFECT GAS FIRE
THIS APPLIANCE IS CAT I
2H
FOR USE WITH NATURAL GAS
ONLY
G20 AT 20mbar
IN G.B. AND I.E.
INSTALLATION & SERVICING
BOOK
ISSUE 2
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the jewel and is the answer not in the manual?

Questions and answers

Summary of Contents for crystal fires jewel

  • Page 1 1 VALENTINES BUILDINGS BECHERS DRIVE AINTREE RACECOURSE BUSINESS PARK AINTREE LIVERPOOL L9 5AY JEWEL DECORATIVE FUEL EFFECT GAS FIRE THIS APPLIANCE IS CAT I FOR USE WITH NATURAL GAS ONLY G20 AT 20mbar IN G.B. AND I.E. INSTALLATION & SERVICING...
  • Page 2 270mm 180mm 465mm 600mm 550mm 180mm SIZES INCLUDING TRIM RADIANT BOX PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE YOU START INSTALLING THE APPLIANCE. KEEP THIS BOOKLET HANDY FOR FUTURE REFERENCE ISSUE 2...
  • Page 3 TECHNICAL DATA GAS TYPE: NATURAL GAS GAS PRESSURE: 20mbar CONNECTION 8mm TUBE INJECTOR manual control: CAT 82/460 BRAY INJECTOR remote control: CAT 82/440 BRAY HEAT INPUT 6.9kW HIGH 4.1kW LOW CAT 1 DATA BADGE ON FRONT BOTTOM SECTION OF APPLIANCE IMPORTANT NOTES THIS APPLIANCE IS FITTED WITH AN ATMOSPHERE SENSING DEVICE AND CAN ONLY BE FITTED IN CONJUNCTION WITH THE FOLLOWING...
  • Page 4 WARNING THIS APPLIANCE HAS A NAKED FLAME, AS WITH ALL SUCH FIRES IT IS RECOMMENDED THAT A FIREGUARD SHOULD BE USED FOR THE PROTECTION OF CHILDREN, THE ELDERLY AND INFIRM. FIRE GUARDS SHOULD CONFORM TO BS8423 2002 (FIREGUARDS FOR FIRES AND HEATING APPLIANCES FOR DOMESTIC USE-SPECIFICATION) INSTALLATION REQUIREMENTS PRE CAST FLUES...
  • Page 5 CONVENTIONAL CHIMNEY A CONVENTIONAL BRICK OR STONE CHIMNEY AS USED FOR SOLID FUEL APPLIANCE WITH A MINIMUM EFFECTIVE CROSS SECTIONAL DIMENSION OF 225*225mm, WITH A MINIMUM OF 3 METERS EFFECTIVE HEIGHT. A LINED FLUE WITH A MINIMUM DIAMETER OF 125mm WITH THE FIREPLACE COMPONENTS CONFORMING TO BS 1251 A BUILDERS OPENING A MINIMUM OF 560mm HIGH AND 400mm WIDE WITH A MINIMUM DEPTH OF 230mm TO ALLOW SUFFICIENT VOLUME OF...
  • Page 6 INSTALLATION REQUIREMENTS FIRETRAY ONLY THE JEWEL FIRETRAY MAY BE INSTALLED INTO A STANDARD FIREBACK OR HOT BOX INSTALLED WITH A CERAMIC FIRE BACK THE INSTALLATION MUST ADHERE TO OPENING SIZES IN FIG 2 THE RELEVANT BRITISH STANDARDS MUST BE FOLLOWED...
  • Page 7 250mm MINIMUM 100mm MINIMUM 545mm 200mm 395mm A CERAMIC FIREBACK TO BS1251 INSTALLED IN A METAL BOX ,CAN BE USED AS A HOTBOX TO HOUSE THE JEWEL FIRETRAY MUST BE TO THE DIMENSIONS SHOWN ABOVE ISSUE 2...
  • Page 8 A BRICK CHAMBER TO THE SIZES IN FIG 2 IN AN EXISTING BRICK OR STONE CHIMNEY A 125mm MINIMUM DIAMETER FLUE LINER CONFORMING TO BS715 MAY BE USED, PROVIDING IT IS SEALED AT THE TOP AND BOTTOM OF THE EXISTING BRICK OR STONE CHIMNEY. NOTE ANY OF THE ABOVE FLUES MUST NOT BE RESTRICTED BY DAMPERS OR REGISTER PLATES, THE FLUE MUST SERVE ONLY ONE APPLIANCE AND...
  • Page 9 FIREPLACE OPENING AND A DEPTH OF 300mm FROM THE FUEL BED ANY COMBUSTIBLE MATERIAL MUST BE REMOVED ABOVE THE OPENING TO A HEIGHT OF 900 mm ABOVE THE HEARTH LEVEL. PURPOSE BUILT SUPERIMPOSED FIRE RESISTANT HEARTHS AND BACK PANELS, SPECIFIED AS SUITABLE BY THE MANUFACTURERS MAY BE USED, OR A SUITABLE PROPRIETARY FIRE SURROUND WITH A 1OO DEGREES C RATING.
  • Page 10 BED AND BURNER, THIS MUST BE REMOVED BY REMOVING FUEL AND BRUSHING ANY DEPOSITS WITH A SOFT BRUSH AND VACUUMING THE BURNER, THEN REPLACE FUEL USING THE FOLLOWING PROCEDURE. JEWEL GAS FIRE FUEL BED LAYOUT TOP VIEW "D" "D" "D"...
  • Page 11 JEWEL GAS FIRE FUEL BED LAYOUT TOP VIEW TOP FUEL PIECES "D" "D" "D" "D" "D" "D" "D" LARGER "D" FUEL "B" "B" PIECES "B" "B" "B" "B" "D" "D" "D" "D" "D" SHOWN "D" "D" "D" "D" "D" "D"...
  • Page 12 FITTING TRIMS FIT THE TRIM WITH FOUR MAGNETS PLACED ON THE VERTICAL SIDE FLANGES OF THE FIREBOX (ONE AT THE TOP AND ONE AT THE BOTTOM) OFFER THE TRIM UP AND PUSH INTO POSITION PLACE FRET CENTRALLY IN FRONT TO COVER THE CONTROLS INSTRUCT USER DEMONSTRATE THE LIGHTING AND EXTINGUISHING PROCEDURES TO THE USER AND REMOVAL AND REFITTING OF THE TRIM FOR CLEANING.
  • Page 13 1 REMOVAL OF FUEL PIECES REMOVE LOOSE FUEL PIECES REMOVE FRONT FIBRE BASE REMOVE MAIN FIBRE BASE 2 REPLACEMENT OF GAS CONTROL REMOVE FUEL SET AS 1 DISCONNECT FIRE AT INLET ELBOW REMOVE FIRETRAY BY UNSCREWING TWO SCREWS AT FRONT BOTTOM SECTION OF FIRE TRAY REMOVE CONTRO KNOB,DISCONNECT GAS CONNECTIONS TO VALVE INCLUDING PILOT CONNECTION AND THERMOCOUPLE CONNECTION...
  • Page 14 CLEANING BEFORE CLEANING ANY PART OF THE FIRE ,ENSURE THAT THE GAS IS TURNED OFF AND FIRE IS COOL. BLACK PAINT. USE ONLY CLEAN DAMP CLOTH ,DO NOT USE ANY CLEANING AGENTS BRASS TRIM USE BRASSO,ENSURING YOU REMOVE THE BRASS TRIM FROM THE APPLIANCE BEFORE CLEANING IMPORTANT THE PAINT AND BRASS FINISH ARE DURABLE BUT WILL BE DAMAGED...
  • Page 15 7D BECHERS DRIVE AINTREE RACECOURSE BUSINESS PARK AINTREE LIVERPOOL L9 5AY JEWEL DECORATIVE FUEL EFFECT GAS FIRE THIS APPLIANCE IS CAT I FOR USE WITH NATURAL GAS ONLY G20 AT 20mbar IN G.B. AND I.E. USERS INSTUCTIONS ISSUE 2...
  • Page 16 USERS INSTRUCTIONS FOR JEWEL GAS APPLIANCE YOUR JEWEL GAS APPLIANCE IS A DECORATIVE LIVE FUEL EFFECT GAS FIRE ,DUE TO ITS NEWNESS THE FIRE MAY GIVE OFF SLIGHT SMELL FOR A SHORT PERIOD AFTER INSTALLATION .THIS IS QUITE NORMAL AND WILL DISAPPEAR AFTER A FEW HOURS OF OPERATION.
  • Page 17 HEAT INPUT HIGH 6.9Kw LOW 4.1Kw gross JET CAT82/460 BRAY PILOT JEWEL DECORATIVE INSERT CRYSTAL FIRES 7 D BECHERS DRIVE L9 5AY THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE RULES IN FORCE AND USED ONLY IN A SUFFICIENTLY VENTILATED SPACE .CONSULT INSTRUCTIONS BEFORE...
  • Page 18 BED AND BURNER, THIS MUST BE REMOVED BY REMOVING FUEL AND BRUSHING ANY DEPOSITS WITH A SOFT BRUSH AND VACUUMING THE BURNER, THEN REPLACE FUEL USING THE FOLLOWING PROCEDURE. JEWEL GAS FIRE FUEL BED LAYOUT TOP VIEW "D" "D" "D"...
  • Page 19 JEWEL GAS FIRE FUEL BED LAYOUT TOP VIEW MIDDLE FUEL PIECES "D" "D" "D" "D" "B" "B" "B" FUEL PIECES "B" "B" CENTRAL REAR "A" "D" "D" LARGE ROUND "D" "D" FUEL PIECES TOUCHING "A" FUEL FONT PIECE "D" PIECES...
  • Page 20 DRIFTWOOD SET UP FOR SUNRISE/JEWEL/SUPER AND LAGOON. ALL PIECES MARKED UNDERNEATH WITH A LETTER LEFT MAIN MATRIX (A) FITS AT REAR OF BURNER AS SHOWN,BEHIND THE TABS OF MATRIX BRACKET. FRONT BASE (B) FITS AS SHOWN ENSURING BOTTOM IN CHANNEL OF MAIN BURNER WITH...
  • Page 21 LEFT DRIFTWOOD PIECE (G),SITS AS SHOWN PIECE G HAS A ROUND CUT OUT TO THE REAR FRONT AND PIECE (D) HAS A LOCATING POINT ,THE CUT OUT FITS ONTO THE LOCATING POINT WITH THE BRANCH RUNNING TO THE REAR AND SLOTTING BETWEEN DRIFTWOOD PIECES (D) &...
  • Page 22 ROYAL COALS LAYOUT ALL PIECES MARKED UNDERNEATH WITH A LETTER SHOWN LEFT MAIN MATRIX (A) FITS AT REAR OF BURNER AS SHOWN,BEHIND THE TABS OF MATRIX BRACKET AND SITTING FLAT FRONT BASE (B) FITS AS SHOWN ENSURING BOTTOM IN CHANNEL OF MAIN BURNER WITH CUT OUTS OVER SCREWS WITH MATRIX AND FRONT BASE FITTED PIECE (C) IS FITTED TO LEFT HAND SIDE...
  • Page 23 PIECE (G) SITS ON TOP OF PIECE (D) USING LOCATION POINT ON RIGHT BRANCH OF PIECE (D) AND HOLE IN PIECE(G) WITH THE BACK RESTING ON REAR MATRIX AND AS FAR LEFT AS POSSIBLE LOCATION POINT PIOECE (J) IS LOCATED ONTOP OF PIECE E AND USING BOTH LOCATION POINTS AND HOLES IN PIECE J TO ALIGN UP LOCATION POINTS...
  • Page 24 JEWEL/SUPER HEATRAVE RANDOM PEBBLE AND RANDOM BLACK FUEL PIECE LAYOUT (20) FIRST 6 RANDOM FUEL PIECES SIT ON TOP OF THE FRONT FIBRE AS SHOWN,ENSURING THEY DO NOT OVERHANG ON TO THE BURNER. THEY MAY HAVE TO BE TWISTED TO FIT CORRECTLY...
  • Page 25: Additional Instructions

    MERTIK MAXITROL REMOTE CONTROL SYSTEM ADDITIONAL INSTRUCTIONS THESE INSTRUCTIONS ARE FOR THE USE ON CRYSTAL FIRES REMOTE CONTROL RANGE OF GAS FIRES ON POSITION OFF POSITION IGNITION /PILOT POSITION FIGURE 1 OPERATION LIGHTING PROCEDURE 1. TURN KNOB A (FIGURE 1) SLIGHTLY LEFT TOWARDS THE IGNITION...
  • Page 26 LEFT OR RIGHT HAND SIDE OF THE FIRE.ENSURE THAT THE GAS PIPE DOES NOT PREVENT THE REMOVAL OF THE BATTERY HOLDER AND SENSOR OR ACCESS TO OPERATE THE GAS CONTROL KNOBS MODIFIED TECHNICAL DATA INJECTOR SIZES SUPER HEATRAVE/SLIMLINE/RUBY/LAGOON CAT 82/460 SAPHIRE CAT 82/420 JEWEL CAT 82/500 ISSUE 2...

Table of Contents