JVC V.NETWORKS VN-C625 Instructions Manual page 39

Jvc dome type network camera instructions
Hide thumbs Also See for V.NETWORKS VN-C625:
Table of Contents

Advertisement

Item
1
Alarm 1/Alarm 2
Message Packet
Alarm FTP
Shutdown
2
Relay Alarm
• Alarm Output
• Go to a preset position
• Return Mode
• Interval
• Black & White
• Message Packet
• Alarm FTP
• Shutdown
3
Retry (1 to 3)
(Continued)
For setting whether to send alarm packets to the PC when there
is alarm input.
Not Available : Do not send alarm packets.
Available
: Send alarm packets.
For operation according to the [Alarm FTP] in the FTP Client
feature when there is alarm input. Please refer to FTP Client
Settings (
Page 50) for details on alarm FTP.
Set Values: Available, Not Available
Set to "Available" to quit all operations upon alarm input. Using
this Shutdown function enables operations of this camera to
end safely even during recording into CF cards.
Not Available : Do not shut down.
Available
: Shut down.
Note
• When this is set to "Available", all alarm input except alarm
output and message packets will be disabled.
Set here to enable the relay alarm function, which is activated
when 2 alarms are received within a preset time interval.
The sequence and time interval for the alarm input can be specified.
When [Alarm Output] is selected, alarm signal output will be
sent to the alarm output terminal on the ceiling mount accord-
ing to the output port settings.
Notes
• A second alarm input enables this relay alarm function,
and alarm will not be activated for this second input.
• Unless the alarm output in the "Alarm Output" tab is
enabled, this function will not be activated even if alarm
output is selected in the alarm input settings. (
* Please refer to the [Alarm 1/2] item for details on the set val-
ues.
For setting the no. of times alarm notification is to be sent to
the "V.Networks Controller". (Set Value: 1 to 3)
Note
• Alarm notification may fail, depending on the LAN
environment in use. If it fails, set the value for alarm
notification to "3". In this case, alarm by the "V.Networks
Controller" itself is set off only once.
Function/Set Value
Initial Value
Not Available
Not Available
Not Available
Not Available
Page 41)
*Please
refer to
the [Alarm
1/2] item
for the
initial
values.
1
39

Advertisement

Table of Contents
loading

This manual is also suitable for:

V.networks vn-c625uVc vn-c625

Table of Contents