Electrical; Circuit Breaker; Fuse - Bruno SRE-1550 Electra-Ride II Installation Manual

Stairway elevator
Hide thumbs Also See for SRE-1550 Electra-Ride II:
Table of Contents

Advertisement

CIRCUIT BREAKER

The on/off switch is built into the circuit breaker which is provided to protect the
battery,controller and motor circuits in the Elevator carriage. It is unlikely that this circuit
breaker will ever trip in normal use, but if the Elevator should fail to operate, check the circuit
breaker and reset it if necessary. If the circuit breaker should trip, determine the cause and
correct the situation.
The most likely cause of a tripped circuit breaker would be a foreign object jamming the rail or
gear rack or overloading the elevator by exceeding its rated load capacity.
A fuse has been provided to protect the battery charging circuit and the Call / Send electronics.
The Elevator is shipped with this fuse installed.
CIRCUIT BREAKER WITH ON/OFF
SWITCH BUILT IN
REPLACING A "BLOWN" FUSE:
[ ]
Turn "OFF" the unit using the "ON" / "OFF" switch on the back of the unit.
[ ]
Disconnect the battery charger from the rail charge lead.
[ ]
Remove carriage cover.
[ ]
Determine and repair any short circuit which may have caused the fuse to blow.
SRE-1550 UL 06-18-2004
antenna shown here
is on commercial units only
47
©2004,1996 BRUNO INDEPENDENT LIVING AIDS, INC.®

ELECTRICAL

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SRE-1550 Electra-Ride II and is the answer not in the manual?

Questions and answers

Scott Moore
April 7, 2025

Do you cut the rail to the specific length I provide you or do I adjust the rail to the length of the stairs? Is the rail shipped in multiple sections to be assembled on site?

1 comments:
Mr. Anderson
April 9, 2025

The Bruno SRE-1550 Electra-Ride II rail is adjusted to the length of the stairs by measuring along a straight line placed on the stairs and adding a specific measurement to custom fit the installation. The rail is shipped in multiple 8-foot sections that are cut and assembled on-site to fit the stairway.

This answer is automatically generated

Table of Contents

Save PDF