Mitsubishi Electric FR-A700 Instruction Manual page 126

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Parameter
Name
Remote output
495
selection
496
Remote output data 1
497
Remote output data 2
503
Maintenance timer
Maintenance timer
504
alarm output set time
505
Refer to Pr. 37.
516 to 519
Refer to Pr. 29.
539
Refer to Pr. 331.
USB communication
547
station number
USB communication
548
check time interval
Refer to Pr. 338 and Pr. 339.
551
549
Refer to Pr. 117.
550, 551
Refer to Pr. 338 and Pr. 339.
Current average
555
time
Data output mask
556
time
Current average
value monitor signal
557
output reference
current
563, 564
Refer to Pr. 52.
569
Refer to Pr. 80.
571
Refer to Pr. 13.
574
Refer to Pr. 95.
575 to 577
Refer to Pr. 127.
611
Refer to Pr. 57.
665
Refer to Pr. 882.
684
Refer to Pr. 82.
800
Refer to Pr. 81.
802
Refer to Pr. 10.
803
Refer to Pr. 22.
Incre
Initial
Range
ments
Value
Remote output data
0
clear at powering off
Remote output data
1
held at powering off
1
0
Remote output data
10
clear at powering off
Remote output data
11
held at powering off
1
0
0 to 4095
Output terminal can be switched on and
off.
1
0
0 to 4095
Display the cumulative energization time of
the inverter in 100h increments.
1
0
0 (1 to 9998)
Reading only
Writing the setting of "0" clears the
cumulative energization time.
Set the time taken until when the
0 to 9998
maintenance timer alarm output signal
1
9999
(Y95) is output.
9999
No function
1
0
0 to 31
Specify the inverter station number.
USB communication is enabled. However,
the inverter will come to an alarm stop (E.
0
USB) if operation is changed to PU
0.1s
9999
operation mode.
0.1 to 999.8s Set the interval of communication check time.
9999
No communication check
Set the time taken to average the current
0.1s
1s
0.1 to 1.0s
during start bit output (1s).
Set the time for not obtaining (mask)
0.1s
0s
0.0 to 20.0s
transient state data.
Set the reference (100%) for outputting the
Rated
signal of the current average value.
0.01/
0 to 500/
inverter
* The increments and setting range differ
0.1A
0 to 3600A
*
*
current
Description
No remote output
data held at
resetting
Remote output
data held at
resetting
according to the inverter capacity. (55K or
less/75k or more)
Parameter List
All
Para
Param
param
meter
eter
eter
copy
clear
clear
: enabled
× : disabled
×
×
×
×
×
×
×
×
×
×
3
121

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents