Summary of Contents for Miele DA 424 V

  • Page 1 Operating and installation instructions Rangehood DA 424 V with extended canopy en - AU, NZ To avoid the risk of accidents or damage to the appliance, it is essential to read these instructions before it is installed or used for the first time.
  • Page 2: Table Of Contents

    Contents Caring for the environment ......... . 3 Warning and Safety instructions .
  • Page 3: Caring For The Environment

    Caring for the environment Disposal of the packing Disposal of your old appliance material or machine The transport and protective packing Electrical and electronic appliances / has been selected from materials which machines often contain materials are environmentally friendly for disposal which, if handled or disposed of and can normally be recycled.
  • Page 4: Warning And Safety Instructions

    Any other usage is at the owner's risk. requirements. Inappropriate use Miele cannot be held liable for damage can, however, lead to personal injury resulting from incorrect or improper use and damage to property.
  • Page 5: Technical Safety

    Faulty components must only be the data plate correspond to the on-site replaced by genuine Miele original electricity supply, otherwise the parts. The manufacturer can only appliance could be damaged. Consult guarantee the safety of the appliance a qualified electrician if in any doubt.
  • Page 6 These models may only be combined with a Miele external motor. This rangehood must not be installed and operated in mobile installations (e.g. on a ship).
  • Page 7 Warning and Safety instructions In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the extractor and the heater are in operation simultaneously, an underpressure in the room of 0.04 mbar (4 pa) is the maximum permissible.
  • Page 8: Correct Use

    Warning and Safety instructions Correct use Do not use the rangehood without the filters in place. This way you will Never use an open flame beneath avoid the risk of grease and dirt getting the rangehood. To avoid the danger of into the appliance and hindering its fire, do not flambé...
  • Page 9: Correct Installation

    Safety regulations prohibit the fitting of a rangehood over solid fuel stoves. All ducting, pipework and fittings must be of non-flammable material. These can be obtained from Miele or from builders' merchants. The appliance must not be connected to a chimney or vent flue which is in use.
  • Page 10: Guide To The Appliance

    Guide to the appliance...
  • Page 11 Guide to the appliance a Cover plate k Touch control for the grease filters b Telescopic tower The indicator lamp for the grease filter touch control lights up when the grease c Canopy filters need to be cleaned. The canopy is not designed to be This control is used to reset the used as a shelf.
  • Page 12: Modes Of Operation

    Modes of operation The rangehood works with . . . air extraction: The air is drawn in, cleaned by the grease filters and directed outside. The rangehood is fitted with a non-return flap, which is closed when the rangehood is switched off. No exchange of room air and outside air can take place.
  • Page 13: Use

    To switch the fan on Automatic switch-off of the Intensive setting You can set the Intensive setting so that it only runs for 10 minutes before reverting automatically to level III. ^ Press the On/Off touch control. The fan runs at power level "II". The indicator lamp will come on.
  • Page 14: Run-On Option

    Run-on option The indicator lamps for fan power levels I and IV will flash if the automatic It is advisable to run the fan for a few switch-off of the Intensive setting is not minutes after cooking has finished to activated.
  • Page 15: To Switch The Lighting On

    To switch the lighting on Safety cut-out The cooktop lighting can be switched Should the rangehood be left on, the on and off independently of the fan. fan will switch off automatically after 10 hours. The lighting will remain on. ^ Briefly press the lighting touch ^ Pressing the On/Off touch control will control to switch on the cooktop...
  • Page 16 Reading the filter operating hours Altering the grease filter operating counter hours counter To check the percentage of time set You can set the operating hours already used: counter to suit the type of cooking you – Select a short time if you roast or fry a lot.
  • Page 17: Adjusting The Height Of The Canopy

    Adjusting the height of the canopy The height adjustment feature on the canopy can be used to – The – / + control lamps show the time which has been set: – adapt the height of the rangehood to 1st lamp from the left = 20 hours suit the installation conditions.
  • Page 18: Cleaning And Care

    Miele Chartered scourers or sponges which have Agent, from Miele, or via the internet at been used previously with abrasive www.miele-shop.com. cleaning agents. These will damage the surface...
  • Page 19: Grease Filters

    Stainless steel surfaces can be cleaned using the Original Miele all purpose microfibre cloth, or with a proprietary non-abrasive cleaning agent designed specifically for use on stainless steel. The grease filters should be cleaned...
  • Page 20 ^ Do not wash at more than 65 °C. If a ^ After replacing the grease filters, Miele dishwasher is being used, press the grease filter touch control select the Sensor wash programme. for approximately 3 seconds to re-set the operating hours counter.
  • Page 21: Changing A Halogen Lamp

    Cleaning and care Changing a halogen lamp ^ Before any cleaning or maintenance work, disconnect the rangehood from the mains supply. Ensure that – it is switched off at the isolator, or – the screw-out fuse is removed (in countries where this is applicable). Exercise caution when changing halogen lamps.
  • Page 22: Appliance Dimensions

    Appliance dimensions Exhaust connection C 150 mm The exhaust connection in the ceiling is not fixed in the centre. This means that installation is also possible if the exhaust opening in the ceiling is not directly aligned above the centre of the cooktop. The difference must not exceed 30 mm in all directions.
  • Page 23: Safety Distance Between Cooktop And Rangehood (S)

    Appliance dimensions Safety distance between cooktop and rangehood (S) The minimum safety distances between the top of a cooktop and the bottom of the rangehood are as follows, unless a greater distance is specified by the manufacturer of your cooking appliance: –...
  • Page 24: Installation

    Installation Before installation, it is important to read the information given on the 2 screws M4 x 8 mm following pages as well as the for securing the tower. "Appliance dimensions" and the "Warning and Safety instructions" at the beginning of this booklet. This is particularly crucial when 4 spacers to use in the event of an using the rangehood at the same...
  • Page 25: Extending Or Limiting The Adjustment Range

    Installation Extending or limiting the adjustment Ensure that the tower is held range securely while carrying out the The height range for the appliance can following steps. Danger of inury. be extended or limited by moving the limit switch. It may be necessary to do this if –...
  • Page 26 Installation ^ Secure the limit switch opposite the guide on the telescopic tower (see illustration). ^ Raise and lower the canopy and check that the limit switch is working. ^ Loosen the top limit switch. ^ Remove the safety screw and push the tower downwards.
  • Page 27: Electrical Connection

    Electrical connection If the switch is not accessible after All electrical work should be installation (depending on country), an undertaken by a suitably qualified additional means of disconnection must and competent person in strict be provided for all poles. accordance with current national For extra safety, it is advisable to install and local safety regulations.
  • Page 28: Operation With Dsm 400 Control Module

    Operation with DSM 400 control module The Miele DSM 400 control module can The components of the central be used to combine the rangehood with extraction system are not supplied as other components. standard by Miele. It enables the following: If in any doubt, the advice of a competent builder must be sought.
  • Page 29: Connection For Air Extraction

    Connection for air extraction – Where ducting is horizontal, it must Important: To avoid the danger of be laid to slope away at at least 1 cm toxic fumes, please observe the per metre. This is to ensure that Warning and Safety instructions. condensate cannot drain back into This is especially crucial when using the rangehood.
  • Page 30: Condensate Trap

    Connection for air extraction Condensate trap Silencer (optional extra) (optional extra) To achieve even further reductions in noise levels, a special silencer can be fitted in the ducting system. In addition to insulating the exhaust ducting, we recommend that a suitable condensate trap is also installed to collect and evaporate any condensate which may occur.
  • Page 31: After Sales Service

    – your Miele Chartered Agent or – Miele You will find the telephone number and address of Miele on the back cover of the manual. Please quote the model and serial number when contacting Miele. These...
  • Page 32: Technical Data

    Technical data Total rated load ....455 W Fan motor ....200 W Variable height motor .
  • Page 36 Alteration rights reserved / 4511 M.-Nr. 09 201 060 / 01...