Cis Assy./Cis Carrier Assy./Scanner Ffc - Epson Stylus CX4300 Service Manual

Color inkjet printer
Hide thumbs Also See for Stylus CX4300:
Table of Contents

Advertisement

EPSON Stylus CX4300/CX4400/CX5500/CX5600/DX4400/DX4450

4.8.2 CIS Assy./CIS Carrier Assy./Scanner FFC

Part/Unit that should be removed before removing Scanner CIS Assy./CIS
Carrier Assy./Scanner FFC
Document Cover / ASF Cover / Support Arm / Scanner Unit / Upper Scanner
Housing
Removal procedure
Do not scratch the Rod Lens Array when removing the CIS Assy.
C A U T I O N
1.
Remove the CIS Assy. from the CIS Carrier Assy.
2.
Disconnect the Scanner FFC from the CIS Assy., and remove the CIS Assy.
Rod Lens Array
CIS Assy.
FFC route
Tab
Figure 4-97. Removing CIS Assy.
DISASSEMBLY/ASSEMBLY
CIS Carrier Assy.
CIS Assy.
Scanner FFC
Connector
3.
Remove the CIS Carrier Assy. from the Timing Belt and the Guide Rail of the
Lower Scanner Housing.
Guide Rail of the
Lower Scanner
Housing
Figure 4-98. Removing CIS Carrier Assy.
Do not damage the Scanner FFC as it is secured with double-sided
C A U T I O N
tape.
4.
Shift the Ferrite Core in the direction of the arrow to release it from the tabs
(x2), and remove the Scanner FFC from the Lower Scanner Housing.
Groove on the Lower
Scanner Housing
Ferrite Core
Figure 4-99. Removing Scanner FFC
Scanner Section
Revision A
CIS Carrier Assy.
Scanner Timing Belt
Scanner FFC
Tape Position