Environmental Specifications - Lenovo 8200 Series Installation Manual

Converged network adapter and intelligent ethernet adapter
Table of Contents

Advertisement

• IEEE: 8021q (VLAN)
• IEEE: 802.3ad (Link Aggregation)
• IEEE: 802.1p (Priority Encoding)
• IEEE: 802.3x (Flow Control)
• IEEE: 802.1Qbb (Priority Based Flow Control)
• IEEE: 802.1Qaz (Enhanced Transmission Selection)
• IPv4 Specification (RFC791)
• IPv6 Specification (RFC2460)
• TCP/UDP Specification (RFC793/768)
• ARP Specification (RFC826)
• SCSI-3 Fibre Channel Protocol (SCSI-FCP)
• Fibre Channel Tape (FC-TAPE) Profile
• SCSI Fibre Channel Protocol-2 (FCP-2)
• Second Generation FC Generic Services (FC-GS-2)
• Third Generation FC Generic Services (FC-GS-3)
• iSCSI (RFC3720)

Environmental Specifications

The environmental specifications are listed in Table 1.
Table 1. Environmental Specifications
Condition
Temperature Ranges
(for Altitude=900m or 2952.75ft)
Temperature Ranges
(for Altitude >900m or 2952.75ft)
Temperature Gradient Maximum per 60 min-
utes.
Humidity Percent Ranges—
Noncondensing
Humidity Gradient Maximum
per 60 minutes
Altitude Ranges—Low Limits
Altitude Ranges—High Limits
Airborne Contaminants—ISA-71 Level
a
200LFM is required to operate at this temperature.
8200 Series Converged Network Adapter and 3200 Series Intelligent Ethernet Adapter
Operating
a
10°C to 55°C
(50°F to 131°F)
b
10°C to n°C
c
(50°F to n°F
)
10°C
20 to 80 percent
(Max. Wet bulb temperature=
d
29°C)
10 percent
–15.2m (–50ft)
3,048m (10,000ft)
d
G1
Non-Operating
–40°C to 65°C
(–40°F to 149°F)
–40°C to 65°C
(–40°F to 149°F)
20°C
5 to 95 percent
(Max. Wet bulb temperature=
d
38°C)
10 percent
–15.2m (–50ft)
10,668m (35,000ft)
d
G1