RECORDING AREA SET SETTING

Main menu 1
<MAIN MENU 1>
1.LANGUAGE/CLOCK SET
->
2.VIDEO INPUT SET
->
3.RECORDING AREA SET
->
4.RECORDING CONDITIONS SET
->
5.NORMAL REC MODE SET
->
6.TIMER SET
->
7.HOLIDAY SET
->
8.ALARM REC MODE SET
->
TO MAIN MENU 2
->
MOVE LINES WITH JOG. SELECT WITH SHUTTLE

TOTAL CAPACITY display

This shows the total recording capacity of the hard disk. This display
cannot be changed except when the hard disk capacity itself is
changed.
With the initial hard disk setting, the normal recording area takes up
80%, the alarm recording area takes up 19% and the archive area
takes up 1% of the disk capacity. The upper limit is 12 GB (15% of
total capacity when using an 80-GB hard disk), so you cannot set a
value greater than this.
The assignment of space to each recording area is displayed as a
percentage of the total. The normal recording area and alarm
recording area together can be set to a maximum of 99% of the total
space.
The archive area cannot be set manually. It is forcibly assigned to a
minimum of 1%. Accordingly, if the normal recording area and the
alarm recording area are set to a total of 85%, the archive area will be
automatically set to 15%.
For example, if the normal recording area is set to 0% and the alarm
recording area is set to 99%, normal recording images will not be
saved onto the hard disk. Only alarm recording images will be saved.
The recording capacity for each recording area should be assigned
according to the requirements of the particular recording location.
If an additional hard disk is added, the increased capacity will be
included in the TOTAL CAPACITY display.
Note:
If you change the assignment of space to each recording area of
the hard disk while recording is in progress, the images which have
been recorded up until that point will be erased. This is because
the hard disk itself is initialized during this operation, so be very
careful when making this kind of setting. If you need to change the
sizes of the recording areas for some reason, make sure that you
make a backup copy of the images on some other medium such as
a computer.
Make sure that the OVERWRITE setting is "OFF" before moving
the cursor to "AREA FULL RESET →" for either the NORMAL
RECORDING AREA or the ALARM RECORDING AREA. (See
page 45.)
When installing an additional hard disk and the MIRRORING of the
HDD SET setting has been set to "ON", the TOTAL CAPACITY
display of RECORDING AREA SET shows a smaller value for the
hard disk capacity.
English
Sub-menus
<RECORDING AREA SET>
TOTAL CAPACITY
NORMAL RECORDING AREA
AREA FULL RESET
ALARM RECORDING AREA
AREA FULL RESET
ARCHIVE AREA
AREA FULL RESET
CAUTION : WHEN THE AREA SETTING IS CHANGED.
THE WHOLE AREA WILL BE INITIALIZED !
Sets the capacity of the archive area.
Archive area
Displays the total hard
disk capacity.
: 80GB
: 80 %
->
: 19 %
Sets the capacity of the normal
->
:
1 %
recording area.
->
Sets the capacity of the alarm recording
area.

Resetting each recording area

Example: Set the normal recording area to 50% and the alarm
recording area to 49%
1
Press the MENU button to select RECORDING AREA SET,
and then turn the shuttle dial clockwise.
The RECORDING AREA SET sub-menu appears, and the cursor
moves to NORMAL RECORDING AREA.
MENU
2
Use the jog dial to move the cursor to the NORMAL
RECORDING AREA setting, and then turn the shuttle dial
clockwise.
"80%" flashes.
3
Use the jog dial to change the setting, for example from
"80%" to "50%", and then turn the shuttle dial clockwise
The cursor moves to ALARM RECORDING AREA.
4
Turn the shuttle dial clockwise.
"35%" flashes.
5
Turn the jog dial to change the setting, for example from 34%
to 49%, and then turn the shuttle dial clockwise.
The cursor moves to AREA FULL RESET.
43
Normal
recording
area
Alarm
recording
area
<RECORDING AREA SET>
TOTAL CAPACITY
NORMAL RECORDING AREA
AREA FULL RESET
ALARM RECORDING AREA
AREA FULL RESET
ARCHIVE AREA
AREA FULL RESET
CAUTION : WHEN THE AREA SETTING IS CHANGED.
THE WHOLE AREA WILL BE INITIALIZED !
: 80GB
: 49 %
->
: 40 %
->
:
2 %
->