2.3 System Data Control

2.3.1 PC Programming

Description
This PBX can be programmed and administered using a PC. There are two programming methods:
1.
On-site Programming: System programming/diagnosis can be performed locally by connecting a PC to
the PBX directly.
2.
Remote Programming: System programming/diagnosis and data upload can be performed from a remote
location.
1.
On-site Programming:
Method
Using the Serial Interface
(RS-232C) port
Using the USB port
Using the LAN interface
Using a modem through an
SLT port
*1
Using an ISDN TA interface
(64 kbps) through an ISDN
Extension Line
*1
If remote access is disabled through system programming, then this on site programming cannot be done.
2.
Remote Programming:
Method
Using a modem (RMT card)
The PBX has a Serial Interface (RS-232C) port which can be used for
either system administration or SMDR (® 1.26.1.1 Station Message
Detail Recording (SMDR)).
The PC is connected to a USB port (USB Module) attached to a DPT.
Available via the MNT port of the IPCMPR/IPCEMPR card.
An RMT card must be installed. Assign the floating extension number
of the analogue remote maintenance (default: 599), and dial this
number from the PC to connect to the PBX.
Assign the floating extension number of the ISDN remote maintenance
(default: 699), and dial this number from the PC to connect to the PBX.
The RMT card is not required for this method.
*1
This method is available only when a user-supplied ISDN TA that
supports CAPI is used.
An RMT card must be installed. The floating extension number of the
analogue remote maintenance must be assigned (default: 599).
PC programming, using a telephone connected in parallel with the
modem, can be done in the following ways:
Direct Access
Dial the DIL/DID/DDI number whose destination is the floating
extension number of the analogue remote maintenance.
Through DISA
Dial the floating extension number of the analogue remote
maintenance using the DISA feature. (® 1.17.6 Direct Inward
System Access (DISA))
Call Transfer
Call an extension (probably the operator), and request a transfer
to the floating extension number of the analogue remote
maintenance. (® 1.12.1 Call Transfer)