Phone System Requirements

Site Requirements

Optional Equipment

Chapter 2: Installing the Voice Mail

Digital Expansion Cards

VANGARD Mail with software version 10.06 or higher. Also requires
VANGARD Mail Cabinet P/N 17770A.
Each digital expansion card (P/N 17774ADIG) provides up to four ports (There are no digital 2-
port cards). A digital port card contains two connectors. Each card on the connector provides two
Voice Mail ports. A VANGARD Mail system supports up to eight ports. The digital VANGARD
Mail is available in either a 4-port or 8-port configurations. If you have a 4-port digital VANGARD
Mail system, you can expand it with 4 additional ports.
Note: The VANGARD Mail Cabinet (P/N 17770A) supports either the digital port card or analog
port cards (P/N 17772A and 17774A). However, you cannot install a digital and an analog
port card in the same system.
Listed below is the required interface equipment for the i-Series phone systems.
Interface equipment for the i-Series phone system:
-
Each analog VM port must be connected to an analog station port on the ASTU Card.
-
For each pair of digital VM ports, you will connect to one digital port. (You will connect-
the Voice Mail to an odd-numbered digital station port. The phone system automatically
reserves the next consecutive even port. When you program the phone system for Voice
Mail, use the odd-numbered port and the next even port.)
-
For every 2 analog VM ports you need,
one RJ14-to-RJ11 adapter and a 2-pair modular line cord
OR
an RJ14 jack, a 2-pair modular cord, and 2-pair station wire.
-
For every 2 digital VM ports, you need:
one 625 modular jack assembly, 2-pair modular line cord and 2-pair station cord.
Take care of this Voice Mail System by observing all site requirements listed below.
Failure to do so may harm the reliability and continued operation of the equipment.
Dust-free site, far away from large motors
Adequate ventilation for the cabinet
Adequate space above and below if you plan to wall-mount the cabinet (for instructions, see
Place the Voice Mail in the Proper Location)
Temperature of 50 — 104°F (10 — 40°C)
Non-condensing humidity of 28 — 85%
Do not place anything on top of this unit or obscure the vents.
Besides the required tools and materials listed above, you might also want to have these items,
which fall into the nice-to-have-but-not-essential category:
Parallel printer (IBM PC-XT or AT compatible) and cable to print reports
UPS as your surge protector to maintain power during an outage.
Installation Requirements