After use it is normal for some water to drip from the spray head for a few moments. This helps
prevent scale build up over prolonged use.
Shower Accessories :-
It is recommend that as well as checking the showerhead as detailed above, the shower unit, riser
rail, hose etc. be cleaned using a soft cloth and that the use of abrasive or solvent based cleaning
fluid be avoided, especially on any plated finishes.
We recommend that before any cleaning, the isolating switch be turned off, thus avoiding accidentally
switching on the shower.
You Must Regularly Inspect The Shower Hose For Wear And Damage. Replace If Necessary,
Or Every Two Years, With Our Approved Part
Periodical Maintenance
Cleaning the Filter
It is recommended that the filter is periodically
cleaned in order to maintain the performance
of the shower. It is essential that this operation
is carried out by a competent person.
WARNING! Switch OFF the electricity at
the isolating switch and the water supply
at the mains before removing the cover.
The inlet filter is situated inside the water inlet
fitting (See Diagram 24).
To gain access to the filter remove the cover
and right hand trim plate. When removing the
cover be careful that you DO NOT tug the
flying lead from the PCB which is attached to
the cover. Disconnect the flying lead from
the reverse of the front cover.
Holding the filter body with a spanner across
the flats, unscrew the top cap on the water
inlet fitting using another spanner.
Inspect the 'O' rings on the filter body for any
damage when removed from the inlet assembly.
When cleaning the filter, DO NOT use a sharp
object, as it will cause damage. It is preferable
to use an old toothbrush or similar
Do not remove the filter mesh from the body
and clean whilst still in position.
Refit the filter making sure it is screwed fully
home. Do not over tighten the filter cap on
reassembly.

Troubleshooting

I
If the performance of the shower deteriorates in service, follow the checks in the "Self Help" table
below before calling out the contractor.
Any one of the simple adjustments could restore the performance.
.
Diagram 24
18
If you are replacing an earlier model of the
Redring Selectronic you will need to remove
the appropriate backplate section subject to
whether the mains water plumbing approach
is either top or bottom entry. See Diagram 2
- Options 'A' or 'B'.
For surface mounted Top entry for plumbing
remove and discard section 'C' and for the
Bottom entry option do likewise with section
'D'.
Make sure the backplate is square on the wall
and tighten the retaining screws which hold it
to the wall.
Turn ON the mains water supply and check for
leaks in the pipework connection to the
shower.
Note: At this stage no water can flow through
the unit.
IMPORTANT: Using a suitable sealant,
always seal around the incoming pipework
through the wall to prevent water entering
the wall.
WARNING! The outlet of the shower
acts as a vent and MUST not be
connected to anything other than the
Hose and Showerhead supplied or
approved by the manufacturer

Electrical Connections

The electrical installation must be in accord-
ance with the current BS7671 (I.E.E. wiring
regulations) and "Part P" of the Building
Regulations and/or local regulations.
The unit is designed for a single phase 50 Hz
a.c. electrical supply.
Please check the rating plate on the unit to
see what details apply to your unit.
A means for disconnection in all poles must
be incorporated in the fixed wiring in accord-
ance with the wiring rules. We recommend
ceiling switches.
I
The cable size required is determined by the
kW rating of the shower and the distance
between the shower and the consumer unit.
The table on Page 8 is for guidance only in
choosing the correct cable for your installation.
If on installation it is the intention to use YT2
conduit trunking to conceal the surface
electrical cable to either the Top or Bottom
21 mm
Diagram 4
IN
OUT
TRIAC
POWER
TEMPS
STEP
FLOW
SOLENOID
INLET
THERMISTOR
OUTLET
STEPPER
THERMISTOR
MOTOR
Wiring Diagram
7
L
E
N

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Selectronic Premier and is the answer not in the manual?

Questions and answers

Andrea clifton
February 9, 2025

I have water coming out the bottom of the unit instead of the hose

1 comments:
Mr. Anderson
February 11, 2025

Water leaking from the bottom of the Redring Selectronic Premier instead of the hose could be due to a blockage in the waterways. The manual advises flushing out the pipework before connecting the water supply to prevent debris from causing obstructions. If debris is present, it may cause water to escape from unintended points, such as the bottom of the unit.

This answer is automatically generated