How To Use Your Shower
I
Your shower has four modes of operation, Normal and three Temperature Lock postions 1, 2 and 3.
(Please see Changing the Operating Mode Templock/Normal section on Page 9)
The Temperature Lock feature ensures a preset maximum temperature is not exceeded.
The shower is factory preset at Locked Position 1 (40 C maximum - temperature range 34 - 40 C).
This can be changed on installation / commissioning for any of the other three options.
Temperature Lock is achieved by limiting the adjustment of the temperature control buttons, so that
the less able, elderly and children cannot accidentally adjust the shower so that it is too Hot.
Button
Location
Function
At The Bottom Of The
Start / Stop
Shower
Warmer
Towards Middle Of The
Shower
Cooler
Directly Below The
Warmer Button
Selectronic
Normal Operation
Switch On Electricity at ceiling / isolating
switch.
Press Start /Stop Button in the centre.
(Confirmed with a single bleep) See Diagram
13
The unit will start and the motorised valve will
reset. Display will show the target temperature
(6) for two seconds and then change to the
actual temperature (Usually "L").
The digit will flash and increase until display
shows number 6. (The average showering
°
Shape / Texture
Large, A Raised Pip In The Centre, Made From
Soft Rubber
Textured Front And A Central Recess With A Raised Plus
Symbol In The Centre. Made From Hard Plastic
Same Shape As Warmer However Smooth With A
Central Recess With A Raised Minus Symbol. Made From
Hard Plastic
Temperature
Premier
Temperature
Lock
Warmer
Cooler
Start/Stop
12
temperature).
When the unit has reached this setting it stops
flashing and sounds a double bleep and the
unit is ready for use.
°
The unit will only count up and double bleep
once per shower session.
To Increase Temperature
Press the warmer button once in the centre
(Confirmed with a single bleep). The number
will change to the new setting. i.e. Display will
change from digit 6 to digit 7. See Diagram 14
Wait for a few seconds for the shower to
increase the temperature to the new setting.
Repeat this for your ideal setting waiting
each time for the temperature to be achieved.
(Maximum setting is letter H).
Please Note! There are eleven temperature
options when the Operating Mode Templock is
set to "Unlocked" which are as follows:- L-1-2-3-
4-5-6-7-8-9-H.
To Decrease Temperature
Press the cooler button once in the centre
(Confirmed with a single bleep)
The number will change to the new setting i.e.
Display will change from digit 6 to digit 5. See
Diagram 15
Wait for a few seconds for the shower to
decrease the temperature to the new setting.
Repeat this for your ideal setting waiting
each time for the temperature to be achieved.
(Minimum setting is letter L)
Please Note! There are eleven temperature
options when the Operating Mode Templock is
set to "Unlocked" which are as follows:- L-1-2-
3-4-5-6-7-8-9-H.
Switching OFF
Diagram 13
When you have finished showering press
the start /stop button in the centre. See
Diagram 16 (Confirmed with 3 short bleeps)
1
The water will continue to run for a few seconds
Audible Short
Bleep
so that the unit is cooled down ready for the
next time the shower is used.
While this is happening the display will circle
round and round (see Diagram 17).
The unit will then switch off automatically.
Switch Off Electricity at ceiling / isolating
switch.
Diagram 14
Audible Short
Bleep
Diagram 15
Audible Short
Bleep
Diagram 16
Audible Short
Bleeps
Diagram 17
13
1
1
3
Need help?
Do you have a question about the Selectronic Premier and is the answer not in the manual?
Questions and answers
I have water coming out the bottom of the unit instead of the hose
Water leaking from the bottom of the Redring Selectronic Premier instead of the hose could be due to a blockage in the waterways. The manual advises flushing out the pipework before connecting the water supply to prevent debris from causing obstructions. If debris is present, it may cause water to escape from unintended points, such as the bottom of the unit.
This answer is automatically generated