20 FUNCTION PORT
Function Name
RX Unlock
Selectable
TOR
TXS
TX Unlock
Note:
# It is possible to configure any voltage value to detect the voltage
decrease/increase. (*1)
(Refer to 10.2 Power Supply Lower
Level, 10.3 RX Signal Detect (Below).)
# It is possible to configure "Power Down Detect" adjustment of
PC Tuning mode to Hi Power and Low Power. This function
notifies a user that the transmission power is suddenly
decreased. However, you cannot use this function as a real-time
power monitor. (*2)
(Refer to 24.2.3 PC Tuning Mode.)
Default: Hi (25 W) power: Approximately 10 W
: Low (1 W) power: Approximately 0.3 W
# When configuring the Activation code to the PF [COR] output
port or the PF [TOR] output port, TKR-750/850/751/851 cannot
activate the repeat operation since it transmits the code while it
is in Busy status, so that it cannot receive the Air Remote code.
(Refer to 18.2.3 Aux Output Activation.)
# Since the status of the Air Remote Encode function is retained
while transmitting using the Repeater PTT, the Local Mic PTT, or
the External PTT, or CW ID, TKR-750/850/751/851 cannot
transmit the Activation code even when the function is activated
while the Activation code is configured to the PF [Power Supply
Lower Limit] output port. In this case, TKR-750/850/751/851
transmits the Activation code after ending the transmission (the
function deactivates). When the Deactivation code is configured
to the port, TKR-750/850/751/851 transmits the Deactivation
code after transmitting the Activation code.
Output Activation, 18.2.4 Aux Output Deactivation.)
! Configuration of KPG-91D
" Configuring the Auxiliary Output ports (Refer to
FPRG 6.10.2 "AUX" tab.)
51
The PF [RX Unlock] output port become active when RX PLL is unlocked.
The PF [RX Unlock] output port become inactive when RX PLL is locked.
You can toggle the PF [Selectable] output port between Active and Inactive when the signal is applied to
an Auxiliary Input port or a PF key.
The PF [TOR] output port become active when a signalling code is matched while receiving a signal.
The PF [TOR] output port become inactive when a signalling code is not matched.
The PF [TOR] output port become active on the channel which a signalling is disabled by QT/DQT
Decode Disable function while receiving a signal.
The PF [TOR] output port is disabled when TKR-750/850/751/851 is not receiving the signal.
The PF [TXS] output port become active while transmitting.
The PF [TXS] output port become inactive when TKR-750/850/751/851 is not transmitting.
The PF [TX Unlock] output port become active when the TX PLL is unlocked.
The PF [TX Unlock] output port become inactive when the TX PLL is locked.
(Refer to 18.2.3 Aux
Function Reference (FUNC)
Description

20.3.1 Logic Type

You can select an Auxiliary Output port output logic type
(High/Low) when the function is assigned to the Auxiliary
Output port.
When the Active Low is selected:
When the Auxiliary Output port is enabled, the voltage
level becomes Low.
When the Active High is selected:
When the Auxiliary Output port is enabled, the voltage
level becomes High.
! Configuration of KPG-91D
" Configuring the Logic Type (Refer to FPRG 6.10.2
"AUX" tab.)