CAUTION
Check that the crimp tool matches the RJ45 connector being used.
Both ends of the ODU cable are terminated in the same way. The above procedure should be
repeated for the PIDU Plus end of the cable when the cable routing process is complete. This
assumes that the installation uses PTP LPUs. If not, then the PIDU Plus end of the cable
does not require a Gland, but just the
NOTE
The PIDU Plus end of the cable does not employ a cable gland.
Figure 24 shows a completed ODU to PIDU Plus cable.

Figure 24 - Completed ODU Connector

CAUTION
Do not over tighten the glands as the internal seal and structure may be damaged.
See Figure 25 for an example of an over tightened cable gland.

Figure 25 - Correct and Incorrect Tightening of Cable Gland

RJ45.
55
6 Installation