Troubleshooting (Fault Finding); Test Link End Hardware - Motorola PTP 500 Series User Manual

Motorola ptp 500 series point-to-point wireless bridges
Hide thumbs Also See for PTP 500 Series:
Table of Contents

Advertisement

9 Troubleshooting (Fault Finding)

This section provides instructions for troubleshooting (fault finding) a PTP 500 link.
Perform the following procedures either on a newly installed link, or on an operational link if
communication is lost:
1. Test the hardware at one end of the link, as described in Section 9.1 "Test Link End
Hardware".
2. Test the hardware at the other end of the link, as described in Section 9.1 "Test Link
End Hardware".
3. Test the radio link, as described in Section 9.2 "Test Radio Link".
4. If an installation has been struck by lightning, see Section 9.3 "Lightning Strike".
9.1

Test Link End Hardware

When the link end hardware (PIDU Plus, LPU, ODU and cabling) has been installed, start it
and test it by following this procedure:
1. Connect the RJ45 from the ODU (or LPU if fitted) to the PIDU Plus and apply mains
or battery power to the PIDU Plus. The green Power LED should illuminate
continuously.
2. After 45 seconds, the yellow Ethernet LED should be observed starting with 10 slow
flashes.
3. Connect the RJ45 from the LAN port of the PIDU Plus to the network. The yellow
Ethernet LED should blink randomly as traffic passes through.
4. If the Power and Ethernet LEDs do not illuminate correctly, test the link end as
described in the flowchart (Figure 105) and detailed test procedures (Sections 9.1.1
to 9.1.7).
9 Troubleshooting (Fault Finding)
161

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ptp 54500Ptp 58500Ptp 300 series

Table of Contents