Download Print this page

Sunvic TLX 7506 User Manual

Rf digital room thermostat

Advertisement

USER GUIDE
TLX 7506
RF Digital Room Thermostat
The TLX 7506 is a Radio Controlled Room Thermostat which
requires no wiring and can be fitted in any normal operating
environment within a typical 30 metre range of the TLX 1206
RF Receiver.
The TLX 7506's unique security code is installed into the RF
Receiver as part of the commissioning procedure ensuring
that your RF Receiver will only respond to instructions sent
to it from your TLX 7506 Transmitter. How this is done is
detailed in the Commissioning Instructions later in this guide.
TLX 7506 Technical Data
o
o
Temperature Range:
5
C to 35
C in 1
o
o
16
C to 35
o
o
Differential:
<1
C at 4
C per Hour
Ambient Temperature:
Operating 0
Power Supply:
Two type AA 1.5V alkaline cells
Battery Life:
2 years typical
Wiring:
No wiring required
Maintenance:
No user maintenance required
Radio signal range:
30 metres typical
Conforms to:
DTI MPT1340 (licence exempt)
Year 2000 compliant in accordance with BSI PD2001
Operation:
The TLX7506 Digital Room thermostat is simple to use.
The large 12mm Liquid Crystal Display continuously shows
actual room temperature.
To display the temperature requested (the Set Point) press
and hold the button marked 'SET'.
button the display will revert back to actual temperature.
To change the 'Set Point' (i.e. the temperature requested)
press and hold the 'SET' button and at the same time press
'+' or '-' to increase or decrease the temperature setting.
The display will continue to show the 'Set Point' until the
'SET' button is released. The display will then show actual
temperature.
When the TLX 7506 instructs your heating system to
switch on a small flame symbol appears at the bottom right
of the display.
the thermostat is calling for the heating system to be on.
Position:
The ideal position to locate the TLX 7506 Digital Room
Thermostat is about 1.5m above floor level, accessible,
reasonably lit and free from extremes of temperature and
draughts.
radiator or where it may be subjected to direct sunlight.
The wireless nature of the installation means that the
thermostat can now be positioned in any room to provide
optimum thermal response rather than to minimise or
simplify the installation wiring.
It is recommended the commissioning procedure be
carried out before fixing the mounting plate to ensure the
o
chosen locations are suitable for transmitting and receiving
C steps
radio signals.
C selectable
Installation:
o
o
C to 45
C
Please read all instalation instructions before proceeding.
The TLX 7506 Digital Room Thermostat is battery powered
(supplied)
and operated by radio control.
electrical connections.
wired thermostat, isolate and make safe the wiring to the
old thermostat as it is no longer required.
All electrical wiring changes must be carried out by a
competent person in accordance with the latest appropriate
Wiring Regulations.
supply before removing any existing thermostat.
Fixing:
1.
The metal mounting plate supplied should be
positioned with a minimum of 70mm clearance to left,
right, above and below to allow adequate airflow.
2.
Fix the mounting plate directly to a flat wall using the
wall plugs and screws provided.
3.
Remove the battery insulation strip protruding from the
On releasing this
rear of the unit. Check the unit is functioning and fit to
the metal mounting plate on the wall.
This symbol will be displayed only when
Do not mount on an outside wall, above a
It does not require any
If it is replacing an existing hard
Be sure to switch off the mains
Configuring:
o
The unit is supplied with a 5
C minimum temperature set
point and configured as a heating thermostat as factory
defaults.
Two internal links can be used to re-configure
these defaults.
1.
Open the unit by slackening the retaining screw on the
lower side and hinge unit upward along the top edge
to separate it from the plastic base. Remove the
batteries.
2.
Locate and identify the two option Links 1 and 2. Use
a pair of small wire cutters to carefully cut the
appropriate links to give the required configuration.
3.
Cutting Link 1 will give a minimum temperature set
o
o
point of 16
C (factory default is 5
display cooling symbol instead of heating symbol.
Please ensure the RF Receiver (TLX 1206) is wired
for a cooling application (i.e. using contacts 2 and 4).
4.
Carefully replace batteries being sure to observe the
correct polarities.
Re-fit plastic base and tighten
retaining screw. Check unit is functioning as required
and fit to metal mounting plate on the wall.
Battery Replacement:
This is the only maintenance required for this product.
A 'flashing' battery low symbol will appear at the bottom
left of the display when the batteries start to approach the
end of their life. This indicates that they should be replaced
within the next month. Normal operation will be maintained
during this period. Ultimately the complete display will start
flashing at which time the thermostat will switch off the
heating and shut down until the batteries are replaced.
To replace the batteries the following procedure should be
carried out.
1.
Remove the unit from the wall-plate by sliding
upwards and gently pulling away from the wall.
Slacken the retaining screw on the unit and open by
hinging upwards along the top edge.
2.
Carefully
remove
batteries
from
compartment and fit two new
'AA' alkaline cells
taking care to observe the correct battery polarities.
Check unit is functioning and re-fit to the plastic base
by hinging downwards from the top edge. Ensure unit
is properly closed and re-tighten the retaining screw.
3.
Re-mount onto the metal wall-plate and check the TLX
7506 is still in radio communication with the RF
Receiver.
This is easily done by adjusting the set
point to switch on and off the heating system several
times and checking the green indicator on the RF
Receiver goes on and off accordingly.
TLX7506_User 16/8/99(Rev.) P.1
C).
Cut Link 2 to
the
battery

Advertisement

loading
Need help?

Need help?

Do you have a question about the TLX 7506 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sunvic TLX 7506

  • Page 1 Re-fit plastic base and tighten thermostat can now be positioned in any room to provide to it from your TLX 7506 Transmitter. How this is done is retaining screw. Check unit is functioning as required optimum thermal response rather than to minimise or detailed in the Commissioning Instructions later in this guide.
  • Page 2: Commissioning

    Checking the RF circuit: Hints and Tips: Commissioning: Press and hold the + and - buttons on the TLX 7506 for This is the process of establishing communication Receiver RED LED ‘steady on’ at least 3 seconds. The TLX 7506 will then transmit its...
Save PDF