TLX1009 Digital Room Thermostat
What is a room thermostat?
A room thermostat simply switches the heating system on and off
as necessary. It works by sensing the air temperature, switching
on the heating when the air temperature falls below the thermostat
Setting, and switching it off once this set temperature has been
reached.
Turning a room thermostat to a higher setting will not make the
room heat up any faster. How quickly the room heats up depends
on the design of the heating system, for example, the size of boiler
and radiators.
Neither does the setting affect how quickly the room cools down.
Turning a room thermostat to a lower setting will result in the room
being controlled at a lower temperature, and saves energy.
The heating system will not work if a time switch or programmer
has switched it off.
The way to set and use your room thermostat is to find the lowest
temperature setting that you are comfortable with, and then leave it
alone to do its job. The best way to do this is to set the room
thermostat to a low temperature – say 18
by one degree each day until you are comfortable with the
temperature. You won't have to adjust the thermostat further. Any
adjustment above this setting will waste energy and cost you more
money.
If your heating system is a boiler with radiators, there will usually
be only one room thermostat to control the whole house. But you
can have different temperatures in individual rooms by installing
thermostatic radiator valves (TRVs) on individual radiators. If you
don't have TRVs, you should choose a temperature that is
reasonable for the whole house. If you do have TRVs, you can
choose a slightly higher setting to make sure that even the coldest
room is comfortable, then prevent any overheating in other rooms
by adjusting the TRVs.
Room thermostats need a free flow of air to sense the
temperature, so they must not be covered by curtains or blocked
by furniture. Nearby electric fires, televisions, wall or table lamps
may prevent the thermostat from working properly.
TLX1009 Room Thermostat
The TLX1009 is a digital electronic room thermostat with
Economy mode (night setback) and Chronoproportional
control (TPI). It has Volt-free switching with 2 wire
installation (no need for a Neutral).

Thermostat position:

To be placed at a height of 1.5m
from the floor. Do not position on an outside wall, above a
radiator, next to a door, or in direct sunlight. This unit must
be installed by a competent person.
For fixed wiring only
Ensure that the fixed wiring connections to the mains
supply (if used) is via a fuse rated at not more than 3 amps
and a class 'A' switch having a contact separation of a
minimum of 3mm in both poles.
o
C – and then turn it up

Installation

N.B. All installations should be carried out by a
competent person and in line with current wiring
regulations
1.
Open the unit by slackening the retaining screw
situated on the bottom edge and hinge carefully
upwards. Disengage the unit from the wall plate
and place it to one side for safe keeping.
2.
Fix the thermostat base plate directly to a flat wall
using plugs and No. 6 x 1" screws, or on to a flush
mounting single conduit box type UA1 (BS4662)
using M3.5 x 14 bolts. Ensure the cable used is
double insulation rated for the application load (2
amps max.).
3.
The thermostat base plate should be positioned
with a minimum of 70mm clearance all around to
allow adequate air flow.
4.
Strip back wire insulation as required and securely
fit wires to terminal block in accordance with the
wiring diagram below. Note an EARTH connection
is not necessary as the TLX 1009 meets the
required double insulation standards.
5.
Fit 2 AA 1.5V Batteries as indicated on base of
battery compartment.
6.
Fit the unit up to the wall plate by hinging from the
top edge and carefully secure with the retaining
screw.
7.
Please ensure this user guide is left for the
householder.
WARNING
The cover must not be removed unless the
thermostat is isolated from the electrical supply.
INTERFERENCE WITH SEALED PARTS
RENDERS GUARANTEE VOID
i
Always replace both (2) batteries at the same time. Only use
1.5 V alkaline batteries of the type LR06 (AA).
Safe Disposal
Do not dispose of batteries with household rubbish. They must be
returned in accordance with the local statutory requirements
In line with a policy of continuous product development, SUNVIC
CONTROLS Ltd. reserve the right to change the specification,
design and materials of products without prior notice.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TLX1009 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sunvic TLX1009

  • Page 1 TLX1009 Room Thermostat The cover must not be removed unless the thermostat is isolated from the electrical supply. The TLX1009 is a digital electronic room thermostat with Economy mode (night setback) and Chronoproportional INTERFERENCE WITH SEALED PARTS control (TPI). It has Volt-free switching with 2 wire RENDERS GUARANTEE VOID installation (no need for a Neutral).
  • Page 2 Please note, when configured for COOL mode, i.e Chronoproportional control (TPI) Jumper J 1 in the ON position, the fan, air-conditioning The Sunvic TLX 1009 electronic room thermostat is a unit etc, is connected to the ON terminal (and not to Chronoproportional or TPI (Time Proportional Integral)

Table of Contents