Canopy  T1/E1 Multiplexer 
 
 
 
Action
Set backup clock
reference line
Set timing mode
Log off
 
Issue 1
 
 
 
 
 
NOTE: This is the optional backup clock reference for all four T1/E1 lines. The
backup clock reference becomes active only when the master clock reference
line is unavailable. The default setting is T1/E1 Port 2.
Enter set secondary clock reference line [1/2/3/4]
where
[1/2/3/4] represents T1/E1 ports 1 through 4.
RESULT: The system responds
Backup clk ref line; [1/2/3/4]
NOTE: Timing mode applies to all four E1 lines. Loopback mode loops the T1/E1
Tx clock to the T1/E1 Rx. Recovered mode recovers the T1/E1 clock from the
incoming T1/E1 over Ethernet bit stream (recovers the clock from the far end
T1/E1). The default timing mode is Recovered.
For master clock timing mode, enter
set clock source loopback
RESULT: The system responds
Clock source is loopback
For slave clock timing mode, enter
set clock source recovered
RESULT: The system responds
Clock source is recovered
Enter lo.
RESULT: The system responds goodbye.
end of procedure
 
 
 
     
 
    T1/E1 Multiplexer Release 3.1 
Steps
 
 
          June 2004 
 42 of 69 