100F
0.1F
Frequency
5.999Hz
0.001Hz
59.99Hz
0.01Hz
599.9Hz
0.1Hz
5.999kHz
0.001kHz
59.99kHz
0.01kHz
599.9kHz
0.1kHz
5.999MHz 0.001MHz
9.999MHz 0.001MHz
Sensitivity: 0.5V rms <500kHz; 3V rms >500kHz
Duty Cycle
0.1 to
0.1%
99.9%
Pulse width: 100µs to 100ms, Frequency: 5Hz
to 150kHz
NOTE: Accuracy is stated at 65
less than 75% RH.
Note: Accuracy specifications consist of two elements:
 (% reading) – This is the accuracy of the measure circuit.
 (+ digits) – This is the accuracy of the A/D converter.
Enclosure
Double molded, waterproof (IP67)
Shock (Drop Test)
6.5 feet (2 meters)
Diode Test
Test current of 0.3mA typical, open
circuit voltage 1.5V DC typical
Continuity Check
Audible signal will sound if the
resistance is less than 100
(approx.), test current <0.3mA
7.8MΩ
Input Impedance
AC Response
Average responding
ACV Bandwidth
50Hz to 400Hz
≤3 at full scale up to 500V,
Crest Factor
Display
4,000 count backlit liquid crystal
Overrange indication
"OL" is displayed
Auto Power Off
30 minutes (approximately)
(5% reading + 5 digits)
(1.5% reading + 1 digits)
(1.2% reading + 3 digits)
(1.5% reading + 4 digits)
(1.2% reading + 2 digits)
o
o
o
o
F to 83
F (18
C to 28
C) and
decreasing linearly to ≤1.5 at
1000V