Product Update: HP Netserver LP 1000r User Guide
IMPORTANT
Replace the information provided in the HP Netserver LP 1000r User Guide
with the updated information provided in this Product Update for each
section that is referred.
In Chapter 6, "Installing an Additional Processor," replace the section "Installing a Heatsink" in
the User Guide with the following section:

Installing a Heatsink

Once the processor is installed, the heatsink must be installed on top of the processor. A thermal patch on the bottom
of the heatsink provides thermal bonding between the heatsink and the processor. The thermal patch must be replaced
if the heatsink is removed (even temporarily) from the processor. You will find extra thermal patches taped to the PCI
card cage inside the server.
1. Remove the heatsink from the shipping container. Do not touch the thermal patch on the bottom of the
heatsink.
2. Inspect the thermal patch. Replace the patch if it is damaged as follows:
a. Make sure you are grounded with a static-dissipating wrist strap.
b. Remove the damaged patch. If you are reinstalling a heatsink on a processor, also scrape off any thermal
material remaining on top of the processor chip. You may use your fingernail to scrape the material off.
c. To install a new thermal patch, peel off the backing, and place the patch in the area marked at the center of
the heatsink.
CAUTION
3. Install the heatsink:
a. Orient the heatsink with the tool latch facing left, as shown in Figure 6-5 following in this Product Update.
Lower the heatsink squarely onto the processor.
CAUTION
b. Hold the heatsink steady with one hand and press the hook latch down to connect it to the tab. Then insert a
flat-head screwdriver into the tool latch and press down to connect the latch to the tab. See Figure 6-6
following in this Product Update.
4. Replace the air duct. See Figure 6-7 in the User Guide. Also, refer to Chapter 2, "Opening and Closing the HP
Netserver."
HP Part Number P1810-90039
Printed in December 2000
Heatsinks are not reusable unless the thermal patch is replaced each time the heat sink is
removed, even if it is temporarily removed and reinstalled on the same processor.
Ensure the heatsink is seated properly on the processor. If the heatsink is offset even slightly,
there will be insufficient thermal contact with the processor, which may result in overheating,
data corruption, and permanent damage to the processor.
'% (&
&'

Advertisement

Table of Contents
loading

Summary of Contents for HP LP 1000r

  • Page 1 See Figure 6-6 following in this Product Update. 4. Replace the air duct. See Figure 6-7 in the User Guide. Also, refer to Chapter 2, "Opening and Closing the HP Netserver."...
  • Page 2 Product Update: HP Netserver LP 1000r User Guide Thumb Latch Tool Latch HP Part Number P1810-90039 Printed in December 2000 Figure 6-5. Placing the Heatsink on the Processor Hold Down Figure 6-6. Setting the Latches Hook Latch (hidden) Step A...
  • Page 3 "Powering Down the Netserver." NOTE The HP Netserver supports a headless boot – that is, the keyboard and mouse do not need to be connected to the Netserver to complete the boot process. In Chapter 3, "Installing Mass Storage Devices," "Introduction" section, in the "Installed Mass Storage Devices"...

Table of Contents