THERMAL FUSE

Refer to page 4-9 for the procedure for ac-
cessing the thermal fuse.
Electric Dryers: The thermal fuse is wired in
series with the drive motor. If the thermal fuse
opens, 91°C (196°F), power to the motor is
turned off. A centrifugal switch on the motor
also opens the heater circuit.
Once the thermal fuse has opened, it will not
reset, and must be replaced. Check for a failed
thermistor, or a shorted heater element.
Gas Dryers: The thermal fuse is wired in
series with the gas valve. If the thermal fuse
opens, 91°C (196°F), power to the valve is
turned off. A centrifugal switch on the motor
also opens the heater circuit.
Once the thermal fuse has opened, it will
not reset, and must be replaced. Check for a
failed thermistor.
Electrical Shock Hazard
Thermal Fuse
91°C (196°F)
1.
Unplug dryer or disconnect power.
2.
Turn off gas supply to dryer.
3.
Disconnect the wires from the thermal
fuse.
4.
Set the ohmmeter to the R X 1 scale.
5.
Touch the ohmmeter test leads to the
thermal fuse terminals. The meter should
indicate continuity (0 Ω). If the meter in-
dicates an open circuit (infinite), replace
the thermal fuse.