GE MDS 4710A Technical Manual page 60

Mds 4710/9710 series 400 mhz and 900 mhz remote data transceivers
Table of Contents

Advertisement

Digital Signal Processing—See DSP. 44
Display
alarm status (STAT command) 31
alarm triggers (AMASK command) 21
all programmed settings (DUMP command) 26
baud rate and encoding (BAUD command) 24
connector port, active (SHOW command) 30
CTS line response timer (CTS command) 25
data handling mode (BUFF command) 24
DC voltage (SHOW command) 30
hardware revision leve (HREV command)l 27
key-up delay (PTT command) 28
model number code (MODEL command) 28
owner's message (OWM command) 28
owner's name (OWN command) 28
radio behavior (DEVICE command) 25
radio serial number (SER command) 30
receive frequency (RX command) 29
receive time-out timer value (RXTOT command) 30, 32
RF forward output power (PWR command) 28
RF output (SHOW command) 30
RSSI (RSSI command) 29
signal-to-noise ratio (SNR command) 30
soft-carrier dekey delay (SCD command) 30
software revision level (SREV command) 31
temperature, internal (TEMP command) 31
time-out value and timer status (TOT command) 31
transmit frequency (TX command) 31
DKEY command 26
DLINK command 26
use of 38
Downloading new software 40
DSP (Digital Signal Processing), defined 45
DSR pinout (Pin 6) 11
DTE (Data Terminal Equipment), defined 45
DTYPE command 26
use of 38
DUMP command 26
E
Earth Ground 10
EEPROM FAILURE error message 19
EMP command 26
Enable/disable
continuous keying (CKEY command) 25
diagnostic channel, pinout (Pin 23) 12
internal RTU (RTU command) 29
network-wide diagnostics (DLINK command) 26
network-wide diagnostics, procedures 38
Environment specifications 36
Equalization, defined 45
Error Messages 19
Error messages 19
access denied 19
command failed 19
EEPROM failure 19
incorrect entry 19
not available 19
not programmed 19
text too long 19
unknown command 19
Event Codes 33
Definitions 34
F
Fade margin, defined 45
I-2
MDS 4710/9710 Technical Manual
Feedlines 9
Filter, helical, adjustment 36
Frame, defined 45
Frequency
adjusting helical filter when changed 36
setting. See TX and RX commands
G
Glossary 44
Ground
on Pin 12 to enable Sleep mode 11
protective (Pin 1) 11
signal (Pin 7) 11
H
Half-duplex 3
switched carrier operation 3
Hand-Held Terminal (HHT) 5
connected to transceiver, illustrated 16
connection and startup 15
display in response to STAT command, illustrated 33
entering commands 17
error messages displayed on 19
keyboard commands 17
operational settings, table 17
reinitialization display, illustrated 16
reinitializing 16
Setup 16
Hardware flow control, defined 45
Helical filter
adjusting 36
illustration 37
Host computer, defined 45
HREV command 27
I
Illustrations
antenna, Yagi 9
Hand-Held Terminal (HHT) connected to transceiver 16
Hand-Held Terminal (HHT) reinitialization display 16
Hand-Held Terminal display in response to STAT
command 33
helical filter locations 37
MAS network 2
network-wide diagnostics 38
point-to-point link 3
remote station arrangement 6
RJ-11 to DB-9 adapter cable 39, 40
RSSI vs. Vdc 12, 15
transceiver connectors & indicators 1
transceiver mounting dimensions 8
INCORRECT ENTRY error message 19
INIT command 27
INIT xx10 command 27
INIT xx20 command 27
InSite software
using to perform remote diagnostics 37, 39
Installation 5–12
antenna 6
configuring transceiver 7
DATA INTERFACE connection 6
data interface connections 11
power 7
power connection 10
steps 6
05-3305A01, Rev. E

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mds 4710m

Table of Contents