34

Event Code Definitions

Table 11
contains a listing of all event codes reported by the transceiver.
Event
Event
Code
Class
Description
01
Major
Improper software detected for this radio model.
02
Major
The model number of the transceiver is unprogrammed.
04
Major
One or both of the internal programmable synthesizer loops is
reporting an out-of-lock condition.
06
Major
An unrecoverable fault was detected on the auto-D chip. The
radio will not receive data.
07
Major
One or more of the radio's internal voltage regulators is
reporting a failure. The radio will not operate.
08
Major
The system is reporting that it has not been calibrated. Factory
calibration is required for proper radio operation.
09
--
Not used.
10
Major
The internal microcontroller was unable to properly program
the system to the appropriate EEPROM defaults. A hardware
problem might exist.
11
--
Not used.
12
Major
Receiver time-out. No data received within the specified
receiver time-out time.
13–15
--
Not used.
16
Minor
Not used.
17
Minor
A data parity fault is detected on the DATA INTERFACE
connector. This usually indicates a parity setting mismatch
between the radio and the RTU.
18
Minor
A data framing error is detected on the DATA INTERFACE
connector. This can indicate a baud rate mismatch between
the radio and the RTU.
19–24
--
Not used.
25
Minor
The 5.6 V power regulator is out-of-tolerance. If the error is
excessive, operation might fail.
26
Minor
The DC input voltage is out of tolerance. If the voltage is too
far out of tolerance, operation might fail.
27, 28
--
Not used.
31
Minor
The transceiver's internal temperature is approaching an
out-of-tolerance condition. If the temperature drifts outside of
the recommended operating range, operation might fail.
MDS 4710/9710 Technical Manual
Table 11. Event Codes
MDS 05-3305A01, Rev. E