Appendix
The projector is detecting abnormal condition.
Indicators
WARNING
POWER
TEMP .
red/green
red
red
red
✽
LAMP REPLACE
When the projection lamp reaches the end of its life, the LAMP REPLACE indicator lights yellow. When this
indicator lights yellow, replace the projection lamp with a new one promptly. Reset the lamp replacement
counter after replacing the lamp. See pages 56-57 .
64
LAMP
WARNING
REPLACE
FILTER
yellow
orange
The temperature inside the projector is abnormally high. The projector
cannot be turned on. When the projector is cooled down enough and
the temperature returns to normal, the POWER indicator lights red
✽
✽
and the projector can be turned on. (The WARNING indicator keeps
blinking.) Check and clean the air filters.
The projector has been cooled down enough and the temperature
✽
✽
returns to normal. When turning on the projector, the WARNING
indicator stops blinking. Check and clean the air filters.
The projector detects an abnormal condition and cannot be turned on.
Unplug the AC power cord and plug it again to turn on the projector. If
the projector is turned off again, unplug the AC power cord and contact
✽
✽
the dealer or the service center for service and checkup. Do not leave
the projector on. It may cause an electric shock or a fire hazard.
The Filter counter reached a set time. Clean or replace the filter as
✽
soon as possible.
Projector Condition