tic
Preqnstallation
Requirements ................................
2
Electrical Requirements ........................................
2
Exhaust System Requirements ............................
3-4
Gas Supply Requirements .....................................
4
Location of Your Dryer..........................................
4-5
Roughqn Dimensions ............................................
6
Mobile Home Installation ......................................
7
Unpacking ...........................................................
7
Reversing Door Swing ...........................................
7-8
Electrical Installation .............................................
9
Grounding Requirements .......................................
9
...............................
10
...............................
10
Gas Connection .....................................................
11
General Installation ................................................
11
Replacement Parts.................................................
11
Before beginning
installation,
carefully
read these instructions.
This wilt simplify
the instaffation
and ensure
the dryer is installed correctly and safely. Leave these instructions
near the Dryer after installation
for future
reference.
NOTE: The electrical service to the Dryer must conform with local codes and ordinances and the latest edition of the
National Electrical Code, ANSI/NFPA 70
NOTE: The gas service to the Dryer must conform with local codes and ordinances and the latest edition of the
National Fuel Gas Code ANS! Z2231
NOTE: The Dryer is designed under ANSI Z 21 51
or ANS!/UL 2! 58 - CAN/CSA C222 (latest editions) for HOME
USE only
This Dryer is not recommended for commercial applications such as restaurants or beauty salons, etc
Save
These
Instructions
Sears, Roebuck and Co., Ho man
Estates, IL 60129 U.S.A.
P/N 134472500 (0410)

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Kenmore 41794252500

  • Page 1: Table Of Contents

    Preqnstallation Requirements ........ Electrical Requirements ........Exhaust System Requirements ......Gas Supply Requirements ........Location of Your Dryer.......... Roughqn Dimensions ..........Mobile Home Installation ........Unpacking ............Reversing Door Swing ........... Electrical Installation ..........Grounding Requirements ........Electrical Connections--3-wire ....... Electrical Connections--4-wire .......
  • Page 2: Electrical Requirements

    POWER SUPPLY - 3 wire or 4-wire, 240 volt, single phase, For your safety the information 60 Hz, Alternating Current. this manual must be followed to minimize the POWER SUPPLY CORD KIT - The dryer MUST employ a risk of fire or explosion or to prevent property 3-conductor power supply cord NEMA I0-30 type SRDT damage, personal injury or loss of life.
  • Page 3: Exhaust System Requirements

    EXHAUST SYSTEM REQUIREMENTS MAX/MUM LENGTH of 4" (10.2 cm) Dia. Rigid Metal Duct Use only 4 inch (! 0.2 cm) diameter (minimum) rigid or VENT HOOD TYPE flexible metal duct and approved vent hood which has a swing-out damper(s) that open when the dryer is in (Preferred) operation.
  • Page 4: Gas Supply Requirements

    Although vertical orientation o f the exhaust system is 2. Tile gas supply line should be of 1/2 inch (127 cm) acceptable, certainextenuating c ircumstances couldaffect pipe. theperformance ofthedryer: 3. If codes allow, flexible metal tubing may be used to Only therigidmetal d uctworkshould beused.
  • Page 5 MINIMUM INSTALLATION CLEARANCES - Inches (cm) SIDES REAR FRONT Alcove 0 (0 cm) 0 (0 cm) 15 (38.1 cm) Closet 0(0cm) 0(0cm) 15(38.1 cm) 1(2.54cm) Closet door ventilation required: 2 Iouvered openings each 60 square inches (387 square centimeters) -- 3 inches (7.6 cm) from bottom and top of door.
  • Page 6 Dryer tnstM/ation Dimensions Free-Standin 9 & Under Counter Electrical supply 48.5" To clear open door on rear of unit (123.19cm) 0 o L_,#, _' Gas supply pipe on rear of unit '91.44cm) I.,T-. (5.72cm) \" °1.-.L- 2.25" 5.0" (12.7cm) Center line height •, right, left...
  • Page 7: Mobile Home Installation

    MOBILE HOME INSTALLATION Using the four shipping carton corner posts (two on each side), Dryer MUST be exhausted outside (outdoors, not beneath the carefully Jay the dryer on its left side and remove the foam mobile home) using metal ducting that will not support shipping base combustion...
  • Page 8 "Window Door" Reversal Instructions: 4. Remove 3. Remove 1. Open the dryer door. Rernove tile four hinge hole phJgs Handle Screws Plastic Plugs from tile left side of the door opening. Place nearby for future installation NOTE: You may need a plastic knife to help pull out the plugs Be careful not to scratch the paint.
  • Page 9: Electrical Installation

    ELECTRICAL INSTALLATION 2. If your dryer is equipped with a power supply cord having an equipment-grounding conductor and a grounding plug, ELECTR/C Dryer the plug MUST be plugged into an appropriate, copper wired receptacle that is properly installed and grounded in accordance with all local codes and ordinances.
  • Page 10: Electrical Connections--3-Wire

    GREEN GREEN POWER CORD ELECTRICAL CONNECTIONS FOR 4-WIRE SYSTEM EL ECTR/C Dryer ELECTRICAL CONNECTIONS Remove the screws securing the terminal block access cover and tile strain relief mounting bracket located on FOR 3-WIRE SYSTEM the back of the dryer upper corner. Install a U.L approved strain relief in the entry hole of ELECTR/C Dryer...
  • Page 11: Gas Connection

    GAS CONNECTION 5. Run the dryer through a cycle check for proper 1. Remove the shipping cap from gas pipe at the rear of operation. the dryer. NOTE: On gas dryers, before the burner will light, it is NOTE; DO NOT connect the dryer to L.R gas service necessary for the gas line to be bled of air.
  • Page 12 Requerimientos de instalacion preliminares ..Requerimientos electricos ....... Requerimientos del sistema de escape.... Requerimientos del suministro de gas....Ubicacion de su secadora ....... Dimensiones para la instalacion ...... Instalacion en casas moviles ......Desembalaje ..........Puerta reversible ..........Instalacion electrica ........Requerimientos para la puesta a tierra ....
  • Page 13 ALIMENTACtON ELECTRICA - Corriente alterna, monof_Ssica, 60 Para su seguridad, siga Ias Hz, 240 voltios; trifilar o tetrafilar instrucciones contenidas en este manual a fin CORDON ELECTRICO - En la secadora se DEBE usar un cordon de reducir a un minimo los riesgos de incendio o elOctrico trifilar...
  • Page 14 REQUERIMIENTOS DEL SISTEMA DE ESCAPE LARGO MAXIMO del Conducto Metblico Rigido de 4" (10,2 cm) de Dibmetro Uti[ice so[amente ductos metalicos, r[gidos o flexib[es de 4" (10,2 cm) de di_imetro (mfnimo) y una caperuza de sa[ida de uso TIPO DE CAPERUZA DE SALIDA aprobado, con registros que giren hada afuera que se abren (Preferido) cuando [a secadora se encuentra en fundonamiento,...
  • Page 15: Ubicacion De Su Secadora

    Aungue unsisterna vertical sea aceptable, algunas circunstancias La tuberia de alirnentaci6n de gas debe ser de 1/2 pulgada atenuantes pueden afectar elfuncionarniento delasecadora: (I ,27 crn) de di_irnetro Se debe utilizar solamente conductos metalicos rigidos. Si est,1 permitido por los c6digos locales, se puede usar...
  • Page 16 DESPEJES MiNIMOS DE INS TA LA CION - Putgadas (cm) Parte Parte Parte Lados Trasera Superior Delantera Alcoba 0 (0 cm) 0 (0 cm) 15(38,1 cm) Armario 0(0cm) 0(0cm) 15(38,1cm) 1(2,54cm) Ventilaci6n requirida en la puerta del armario: dos aberturas rejilladas cada 60 pulg_2 (387 cm2) -- 3"...
  • Page 17 Dimensiones De la InstalacI_n Fuente e[_ctriea en [a parte posterior de ta unidad OOi, Pipe de [a fuente en [a parte posterior de [a unidad I.'1-, r" • ..I.-.L 5.0" (12.7cm) _1 _ L{nea aitura de ¢entro para el respiradero posterior, _i?? derecho,...
  • Page 18: Instalacion En Casas Moviles

    INSTALA CION EN CASA5 MOWLES MODELO5 A UTONOMOS CON CONSOLA 1, El tubo de escape de la secadora DEBE set instalado hacia el SUPERIOR exterior (El escape debe colocarse en la parte exterior y no DtMENSIONES PARA LA INSTALACI6N debajo de la casa m6vik) Debe usarse ducto de metal...
  • Page 19 lnstrucdones De la Revocadon De la Puerta De la Ventana 3. Quite Los 4. Quite Los Tornillos De la Tap6ns PBsticos 1, Abra [a puerta del secador, Quite los cuatro tap6ns del Manija agujero de la bisagra del lado izquierdo de la abertura de la puerta, Coloque cerca para la instalaci6n futura.
  • Page 20 INS TALA OON ELECTRfCA SecadorasELECTR/CAS La conexi6n indebida del conductor de puesta a _ !_ Los siguientes requerimien tos son tierra deJ equipo puede ocasionar un riesgo de choque eJ@ctrico especificos para el funcionamiento correcto y seguro de su Consulte con un eJectricista profesionaJ si tiene alguna duda respecto secadora°...
  • Page 21 TORNILLO TORNILLO VERDE CONDUCTOR VERDE DE VERDE DE PUESTA CORDON ELECTRICO BORNE PLATEADO PUESTA A TIERRA TIERRA BORNE PLATEADQ /!TABLERO DE BORNES CABLE PUESTA A TIERRA NEUTRAL CABLE PUESTA A TIERRA NEGRO ATORNILLE /LANCO TUERCA EN ESTAS ROSCAS TUERCA TORNILLE LA TUERCA EN ESTAS ROSCAS...
  • Page 22: General Instalacion

    CONEXtON Saque la tapa de embarque de la tuberfa de gas de la Haga funcionar la secadora durante un ciclo completo para secadora situada en la parte trasera comprobar su buen funcionamiento_ NOTA: En Jas secadoras a gas, antes de encender el quema- NOTA: NO conecte...