2-4 Other Settings with V.Networks Setup Tool [2. Alarm Setting] (continued)
Alarm input
Item
1
Alarm1/Alarm2
Mode
Detect Mode
Alarm Output
Go to a preset
position
Return Mode
Interval
34
Function & Setting
For configuration of settings related to alarm input.
For selecting whether to enable or disable the input sig-
nals.
Not Available : Enabled
Available
: Disabled
For selecting the method for detecting input signals.
Make
: Detect the input signals at the "Make" con-
tact point.
Brack
: Detect the input signals during "Break".
Toggle
: Detect input signals at both "Make" and
"Break" contact points.
For setting whether to output from the alarm output termi-
nal when there is alarm input.
Not Available : Do not output from the alarm output ter-
minal.
Output 1
: Send alarm output from the Output1 ter-
minal.
Output 2
: Send alarm output from the Output2 ter-
minal.
For setting whether to move to the preset position when
there is alarm input.
Not Available : Move to the preset position.
Home
: Move to the home position.
1 to 99
: Move to the moved position.
For setting whether to return the camera that has been
moved to the preset position upon the alarm input back to
the initial position. Use [Interval] to set the time interval
prior to returning to the initial position.
Not Available : Do not return to the initial position.
Return
: Return to the initial position.
Event
: Return to the initial position except when
this is performed manually.
For setting the time interval prior to returning to the initial
position when [Return Mode] is set to "Return".
Initial Value
Not Available
Mark
Not Available
Not Available
Not Available
0