Resetting; Troubleshooting - Braeburn 1200 User Manual

Builder series non-programmable 2 heat / 1 cool heat pump thermostat
Table of Contents

Advertisement

ADDITIONAL
5
OPERATION FEATURES
Resetting The Thermostat
5.4
The Reset feature allows the user to completely reset the thermostat and to register new
manual ˚F / ˚C temperature scale switch settings.
1. To erase all entered program settings, gently press RESET button using a paper clip or a
small pencil tip.
2. This will return all thermostat settings to their default values and register all new manual
˚F / ˚C temperature scale switch settings.
Non-Volatile Memory
5.5
In the event of a power failure, the Non-Volatile Memory feature of this unit allows all settings to
be recovered, eliminating the need to reset temperature and differential settings. When AC
power is restored after an outage, all settings are retrieved from memory and reinstated.
6

TROUBLESHOOTING

SYMPTOM
POTENTIAL SOLUTION
Thermostat does not
Check to see if OFF is shown in display. This indicates that the
system is turned off at the thermostat. Move the system selector
turn on heating or
switch to the HEAT or COOL position. After the compressor short
cooling system.
cycle protection 5-minute period expires the system should start
within a minutes time.
Compressor protection features may be in effect due to
compressor short cycle conditions. See Compressor Protection
section for full explanation of this feature.
Heat Pump may be malfunctioning. If heating is required, you
can slide the system switch to EMER setting, which will start
the Emergency Heat source to provide heating until the heat
pump can be serviced.
Thermostat turns
Check thermostat wiring to make sure that the heating and
cooling stages are connected to the correct terminals on the
on heating instead
wiring terminal block. See Installation and Wiring Diagram
of cooling, or
sections of this manual.
cooling instead of
heating.
Thermostat turns
Increase or decrease first stage temperature differential setting
as appropriate to provide the desired performance level. See
heating or cooling
Setting Temperature Differential.
system on too often
or not often enough.
cont.
6
6
TROUBLESHOOTING
SYMPTOM
POTENTIAL SOLUTION
Thermostat turns on
Increase or decrease second (auxiliary) stage temperature
differential setting as appropriate to provide the desired
second (auxiliary)
performance level. See Setting Temperature Differential.
stage of heating or
cooling too quickly or
not quickly enough.
OFF is shown in
This indicates that the system is turned off at the thermostat.
Move the system selector switch to the HEAT or COOL position.
thermostat display
After the compressor short cycle protection 5-minute period
and heating or
expires the system should start within several seconds.
cooling system will
not start.
Thermostat display
It is possible that AC power is not present at the thermostat.
Check fuse, circuit breaker and thermostat wiring as appropriate
is blank.
to verify AC power is available.
If AC Power is present, call a professional service technician
immediately to verify thermostat and system performance.
HI is shown in the
The temperature sensed by the thermostat is higher than the
90˚ F (32˚ C) upper limit of the thermostats display range. The
thermostat display
display will return to normal after the sensed temperature
where the room
lowers within the 45˚ to 90˚ F (7˚ to 32˚ C) display range. Turn on
temperature is
the cooling system or use other methods to lower the
normally displayed.
temperature accordingly.
This condition could occur from the system being turned off
during an exceptionally warm period or upon installation when
the thermostat has been stored for a long period of time in a
warm vehicle or location prior to being installed. The thermostat
is equipped with a mechanical high temperature safety switch
that will turn off the thermostat should the temperature exceed
99˚ F (37˚ C).
LO is shown in the
The temperature sensed by the thermostat is lower than the
45˚ F (7˚ C) lower limit of the thermostats display range.
thermostat display
The display will return to normal after the sensed temperature
where the room
rises within the 45˚ to 90˚ F (7˚ to 32˚ C) display range. If the
temperature is
temperature in the controlled space seems to be normal,
normally displayed.
wait for the thermostat to acclimate to the correct room
temperature. If the room seems to be colder than usual, turn
on the heating system to raise the temperature as needed for
comfort within the room.
This condition could occur from the system being turned off
during a cold weather period or upon installation when the
thermostat has been stored for a long period of time in a cold
vehicle or location prior to being installed. The thermostat
should be allowed to warm up prior to installation to allow
proper heating control once installed.
cont.
7

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1200 and is the answer not in the manual?

Questions and answers

Larry
April 7, 2025

In cool mode the room temperature does not reflect the actual temperature the room actual temperature is lower than what is shown

1 comments:
Mr. Anderson
April 7, 2025

The Braeburn 1200 may show a higher temperature than the actual room temperature in cool mode because the thermostat needs time to acclimate to the correct room temperature. This can happen if the thermostat was stored in a cold location before installation or if it was turned off during a cold period. Allowing the thermostat to warm up helps it display the correct temperature.

This answer is automatically generated