Table 13. Full-Height Servers Per Power Supply Configuration - Dell PowerEdge M1000e Technical Manual

Modular blade enclosure
Hide thumbs Also See for PowerEdge M1000e:
Table of Contents

Advertisement

Dell recommends that all customers running a power-hungry configuration should install the
modular iDRAC with Lifecycle Controller firmware 3.02 upgrade, which contains the following
enhancements:
Improved calculation for power budgeting to enable more servers to be powered up
simultaneously.
Functionality to enable iDRAC with Lifecycle Controller to retry power up for blade servers
automatically in the event that some servers do not power up initially due to the pre-boot power
inventory.
Full-height blade servers
Table 13 lists the maximum number of recommended half-height blade servers per power supply
configuration according to the following server definitions:
Light configuration: 2 x 95W processor, 4 DIMMs
Medium configuration: 4 x 105W or 2 x 130W processors, 16 DIMMs
Heavy configuration: 4 x 105W or 2 x 130W processors, 32 DIMMs
Table 13.
Number of servers with
Power supply
configuration
2+1
2+2
3+0
3+1
3+3
4+1
Any server combination
4+2
5+1
1
With sufficient facility power available
The following information is applicable for full-height blade servers:
Throttling (performance reduction to conserve power):
220-240V power:
2 PSUs — Throttling will occur if heavily configured blades are worked very hard at the
>
same time.
3 PSUs:
>
o 4 processors — Some throttling will occur if heavily configured blades are worked
hard at the same time. Minimal throttling is expected for 16-DIMM configurations.
o 2 processors — Throttling may occur if all servers are run under a very heavy load and
have 130W processors and/or 32 DIMMs populated. Minimal throttling is expected
with 95W processors and/or 16 DIMMs.
PowerEdge M1000e Technical Guide
45
Full-height servers per power supply configuration
220–240V power
2700W PSUs
8 light,
7 medium, or
5 heavy
Number of servers with
220–240V power
2360W PSUs
8 light,
5 medium, or
4 heavy
8 light,
8 medium, or
7 heavy
Any server combination
Number of servers with
100–120V power
1
2700W/1350W PSUs
3 light,
2 medium, or
1 heavy
6 light,
4 medium, or
3 heavy
8 light,
6 medium, or
4 heavy
8 light,
8 medium, or
6 heavy

Hide quick links: