Appendix A Event Notification Message List
A.2 Message List
Event type
code
xx
M 13CF11
xxx
M 21810
xxx
M A0110
M A0410
xxx
xxx
M A0810
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
SNMP Trap
Trap
Trap
Maintenance
No.
Info
xx
7
13CF11
REC Buffer HALT occured.(
Occurrence of HALT in the REC Buffer is detected.
xx
: 00, 01, or 02
00: Path error
01: Overload
02: Error
xxx
7
21810
RAID Group#0
Rebuild to the hot spare or the replaced drive is complete,
but Bad Data (data lost identifier) exists.
xxx
: RAID group number (hexadecimal)
xxx
7
A0110
RAID Group#0
Rebuild to the hot spare has not started.
xxx
: RAID group number
7
A0410
xxx
RAID Group#0
Rebuild to the hot spare has started.
xxx
: RAID group number (hexadecimal)
xxx
7
A0810
RAID Group#0
Rebuild to the hot spare is complete.
xxx
: RAID group number (hexadecimal)
127
Copyright 2013 FUJITSU LIMITED
Upper: Message
Lower: Description
xx
)
xxx
recovered end of Rebuild processing
xxx
start failure of Rebuild processing
xxx
start procedure of Rebuild processing
xxx
normal end of Rebuild processing
Remarks
These messages are
notified when the fol-
lowing items are
enabled for Error
Severity Level in the
event notification
setting:
REC Buffer Halt
(Path Error)
REC Buffer Halt
(Overload)
REC Buffer Halt
(Other Error)
These messages are
not notified during
maintenance opera-
tions.
This message is noti-
fied when "Complete
rebuild" is enabled for
Error Severity Level in
the event notification
setting.
This is not notified
during maintenance
operations.
These messages are
notified when
"Rebuild/Copyback w/
o redundant" is
enabled for Error
Severity Level in the
event notification
setting.
They are not notified
during maintenance
operations.
This message is noti-
fied when "Rebuild/
Copyback w/ redun-
dant" is enabled for
Error Severity Level in
the event notification
setting. This is not
notified during main-
tenance operations.